{"id":10487,"date":"2024-07-29T18:38:54","date_gmt":"2024-07-29T18:38:54","guid":{"rendered":"https:\/\/chevrierinstruments.com\/produit\/data-logging-light-meter\/"},"modified":"2024-07-29T19:11:59","modified_gmt":"2024-07-29T19:11:59","slug":"data-logging-light-meter","status":"publish","type":"product","link":"https:\/\/chevrierinstruments.com\/en\/produit\/data-logging-light-meter\/","title":{"rendered":"Data Logging Light Meter"},"content":{"rendered":"<p>The R8100SD has a wide measurement range up to 100,000 Lux (10,000 Foot-candles) and features Data hold, Max\/Min functions, and an easy-to-read backlit LCD display. Using a SD card (max 16GB), a user can manually record up to 99 readings or automatically by selecting a desired sampling rate from 1 to 3600 seconds. Quickly generate an Excel file with raw data, all without the use of software. Optional accessories include a tripod and AC adapter for continuous long-term monitoring.<\/p>\n<h3>Features<\/h3>\n<ul>\n<li>Measures ambient light levels in Foot-candles or Lux<\/li>\n<li>Photo diode and colour correction filters meet C.I.E. spectrum specifications<\/li>\n<\/ul>\n<ul>\n<li>Contact temperature measurement with a type J\/K thermocouple option<\/li>\n<li>Temperature is measured in \u00b0C or \u00b0F<\/li>\n<li>Real-time data logger with integrated SD memory card<\/li>\n<li>User selectable sampling rate from 1 to 3600 seconds<\/li>\n<li>Easy-to-read backlit LCD display<\/li>\n<li>Data hold and Min\/Max functions<\/li>\n<li>Tripod mount for long-term monitoring<\/li>\n<li>Low battery indicator and auto shut off<\/li>\n<\/ul>\n<h4>What's included with the REED R8100SD<\/h4>\n<ul>\n<li>Data Logging Light Meter<\/li>\n<li>Detachable Light Sensor<\/li>\n<li>Sensor Cover<\/li>\n<li>Soft Carrying Case<\/li>\n<li>Batteries<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<h2>R8100SD<\/h2>\n<p>Real-time data logger with integrated SD memory card measures\/records ambient light levels in Foot Candles or Lux and contact temperature with optional type J\/K thermocouple probe.<\/p>\n","protected":false},"featured_media":10477,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[1615,1427,68],"product_tag":[1538,328],"class_list":{"0":"post-10487","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-light","7":"product_cat-luxmeter","8":"product_cat-luminosity","9":"product_tag-data-logging-light-meter","10":"product_tag-digital-luxmeters","12":"first","13":"instock","14":"shipping-taxable","15":"product-type-simple"},"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Data Logging Light Meter - Chevrier Instruments inc.<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/chevrierinstruments.com\/en\/produit\/data-logging-light-meter\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Data Logging Light Meter - Chevrier Instruments inc.\" \/>\n<meta property=\"og:description\" content=\"R8100SD Real-time data logger with integrated SD memory card measures\/records ambient light levels in Foot Candles or Lux and contact temperature with optional type J\/K thermocouple probe.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/chevrierinstruments.com\/en\/produit\/data-logging-light-meter\/\" \/>\n<meta property=\"og:site_name\" content=\"Chevrier Instruments inc.\" \/>\n<meta property=\"article:modified_time\" content=\"2024-07-29T19:11:59+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2024\/07\/REED-R8100SD-Image-A.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"950\" \/>\n\t<meta property=\"og:image:height\" content=\"2211\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/chevrierinstruments.com\/en\/produit\/data-logging-light-meter\/\",\"url\":\"https:\/\/chevrierinstruments.com\/en\/produit\/data-logging-light-meter\/\",\"name\":\"Data Logging Light Meter - Chevrier Instruments inc.\",\"isPartOf\":{\"@id\":\"https:\/\/chevrierinstruments.com\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/chevrierinstruments.com\/en\/produit\/data-logging-light-meter\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/chevrierinstruments.com\/en\/produit\/data-logging-light-meter\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2024\/07\/REED-R8100SD-Image-A.jpg\",\"datePublished\":\"2024-07-29T18:38:54+00:00\",\"dateModified\":\"2024-07-29T19:11:59+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/chevrierinstruments.com\/en\/produit\/data-logging-light-meter\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/chevrierinstruments.com\/en\/produit\/data-logging-light-meter\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/chevrierinstruments.com\/en\/produit\/data-logging-light-meter\/#primaryimage\",\"url\":\"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2024\/07\/REED-R8100SD-Image-A.jpg\",\"contentUrl\":\"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2024\/07\/REED-R8100SD-Image-A.jpg\",\"width\":950,\"height\":2211},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/chevrierinstruments.com\/en\/produit\/data-logging-light-meter\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\/\/chevrierinstruments.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Data Logging Light Meter\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/chevrierinstruments.com\/en\/#website\",\"url\":\"https:\/\/chevrierinstruments.com\/en\/\",\"name\":\"Chevrier Instruments inc.\",\"description\":\"La r\u00e9f\u00e9rence en instruments de mesure\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/chevrierinstruments.com\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Data Logging Light Meter - Chevrier Instruments inc.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/chevrierinstruments.com\/en\/produit\/data-logging-light-meter\/","og_locale":"en_US","og_type":"article","og_title":"Data Logging Light Meter - Chevrier Instruments inc.","og_description":"R8100SD Real-time data logger with integrated SD memory card measures\/records ambient light levels in Foot Candles or Lux and contact temperature with optional type J\/K thermocouple probe.","og_url":"https:\/\/chevrierinstruments.com\/en\/produit\/data-logging-light-meter\/","og_site_name":"Chevrier Instruments inc.","article_modified_time":"2024-07-29T19:11:59+00:00","og_image":[{"width":950,"height":2211,"url":"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2024\/07\/REED-R8100SD-Image-A.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/chevrierinstruments.com\/en\/produit\/data-logging-light-meter\/","url":"https:\/\/chevrierinstruments.com\/en\/produit\/data-logging-light-meter\/","name":"Data Logging Light Meter - Chevrier Instruments inc.","isPartOf":{"@id":"https:\/\/chevrierinstruments.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/chevrierinstruments.com\/en\/produit\/data-logging-light-meter\/#primaryimage"},"image":{"@id":"https:\/\/chevrierinstruments.com\/en\/produit\/data-logging-light-meter\/#primaryimage"},"thumbnailUrl":"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2024\/07\/REED-R8100SD-Image-A.jpg","datePublished":"2024-07-29T18:38:54+00:00","dateModified":"2024-07-29T19:11:59+00:00","breadcrumb":{"@id":"https:\/\/chevrierinstruments.com\/en\/produit\/data-logging-light-meter\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/chevrierinstruments.com\/en\/produit\/data-logging-light-meter\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/chevrierinstruments.com\/en\/produit\/data-logging-light-meter\/#primaryimage","url":"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2024\/07\/REED-R8100SD-Image-A.jpg","contentUrl":"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2024\/07\/REED-R8100SD-Image-A.jpg","width":950,"height":2211},{"@type":"BreadcrumbList","@id":"https:\/\/chevrierinstruments.com\/en\/produit\/data-logging-light-meter\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/chevrierinstruments.com\/en\/"},{"@type":"ListItem","position":2,"name":"Data Logging Light Meter"}]},{"@type":"WebSite","@id":"https:\/\/chevrierinstruments.com\/en\/#website","url":"https:\/\/chevrierinstruments.com\/en\/","name":"Chevrier Instruments inc.","description":"La r\u00e9f\u00e9rence en instruments de mesure","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/chevrierinstruments.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/product\/10487","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/media\/10477"}],"wp:attachment":[{"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/media?parent=10487"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/product_brand?post=10487"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/product_cat?post=10487"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/product_tag?post=10487"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}