{"id":11973,"date":"2024-10-11T18:31:53","date_gmt":"2024-10-11T18:31:53","guid":{"rendered":"https:\/\/chevrierinstruments.com\/produit\/heated-humidity-probe\/"},"modified":"2025-04-01T17:11:46","modified_gmt":"2025-04-01T17:11:46","slug":"heated-humidity-probe","status":"publish","type":"product","link":"https:\/\/chevrierinstruments.com\/en\/produit\/heated-humidity-probe\/","title":{"rendered":"Heated dewpoint &#038; hygrometry probe"},"content":{"rendered":"<p>Stainless steel body and sintered filter. Length 100 mm (3.94\u2019\u2019), \u00d8 13 mm (0.51\u2019\u2019).<\/p>\n<p>It provides the <strong>dew point and freezing point<\/strong> as a measurement. The <strong>relative humidity value<\/strong>, as well as other psychrometric values, can be calculated<span style=\"text-decoration: underline;\"> when the Si-PRO-T-150 temperature probe or a Pt100 probe is connected to the Si-C320 sensor-transmitter<\/span> using the Si-ACCETP adapter.<\/p>\n<p>Main applications: industrial processes, air handling units, drying processes, pharmaceutical production.<\/p>\n<p>The Si-ACC-R2 cable is required for connection to Class 320 sensors-transmitters.<\/p>\n<ul>\n<li>Heated probe, minimizes condensation on the sensor<\/li>\n<li>High accuracy and long-term stability<\/li>\n<li>Pollution resistant<\/li>\n<li>Detachable probe cable for easy installation<\/li>\n<\/ul>\n<h4>Measuring ranges<\/h4>\n<ul>\n<li>Relative humidity 0.00 % RH ... 100.00 % RH (a secondary temperature probe is required)<\/li>\n<li>Wet bulb temperature (calculated parameter) -50.00 \u00b0Ctw ... 100.00 \u00b0Ctw \/-58.00 \u00b0Ftw ... 212.00 \u00b0Ftw<\/li>\n<li>Dew point (calculated parameter) -50.00 \u00b0Ctd ... 100.00 \u00b0Ctd \/\u00a0-58.00 \u00b0Ftd ... 212.00 \u00b0Ftd<\/li>\n<li>Freezing point (calculated parameter) -50.00 \u00b0Ctf ... 100.00 \u00b0Ctf \/\u00a0-58.00 \u00b0Ftf ... 212.00 \u00b0Ftf<\/li>\n<li>Absolute humidity (calculated parameter) 0.00 g\/m\u00b3 ... 1000.00 g\/m\u00b3<\/li>\n<li>Enthalpy (calculated parameter) 0.00 kj\/kg ... 15000.00 kj\/kg<\/li>\n<li>Mixture ratio (calculated parameter) 0.00 g\/kg ... 1000.00 g\/kg<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<h2>Si-PRO-U-I-100-H<\/h2>\n<p>For demanding processes and climate control applications<br \/>\nThe Si-PRO-U-I-100-H is an interchangeable, heated hygrometry probe for Si-C320 transmitters and it has been designed for being used in environments where there is constant high humidity or rapid oscillanting humidity where the probe\u2019s performance and its tolerance to pollutants are key.<\/p>\n","protected":false},"featured_media":7818,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[1518,1519,510,1129,465],"product_tag":[1265,1823,1824],"class_list":{"0":"post-11973","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-humidity-and-temperature","7":"product_cat-sensors-transmitters","8":"product_cat-accessories","9":"product_cat-for-sensors-transmitters","10":"product_cat-humidity","11":"product_tag-accessories-for-multifonctions-sensors","12":"product_tag-heated-humidity-probe","13":"product_tag-probe-for-sensor-transmitters-class-320","15":"first","16":"instock","17":"shipping-taxable","18":"product-type-simple"},"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Heated dewpoint &amp; hygrometry probe - Chevrier Instruments inc.<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/chevrierinstruments.com\/en\/produit\/heated-humidity-probe\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Heated dewpoint &amp; hygrometry probe - Chevrier Instruments inc.\" \/>\n<meta property=\"og:description\" content=\"Si-PRO-U-I-100-H For demanding processes and climate control applications The Si-PRO-U-I-100-H is an interchangeable, heated hygrometry probe for Si-C320 transmitters and it has been designed for being used in environments where there is constant high humidity or rapid oscillanting humidity where the probe\u2019s performance and its tolerance to pollutants are key.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/chevrierinstruments.com\/en\/produit\/heated-humidity-probe\/\" \/>\n<meta property=\"og:site_name\" content=\"Chevrier Instruments inc.\" \/>\n<meta property=\"article:modified_time\" content=\"2025-04-01T17:11:46+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2023\/10\/Sauermann-SI-PRO-UI-100-H_2.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1300\" \/>\n\t<meta property=\"og:image:height\" content=\"1300\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/chevrierinstruments.com\/en\/produit\/heated-humidity-probe\/\",\"url\":\"https:\/\/chevrierinstruments.com\/en\/produit\/heated-humidity-probe\/\",\"name\":\"Heated dewpoint & hygrometry probe - Chevrier Instruments inc.\",\"isPartOf\":{\"@id\":\"https:\/\/chevrierinstruments.com\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/chevrierinstruments.com\/en\/produit\/heated-humidity-probe\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/chevrierinstruments.com\/en\/produit\/heated-humidity-probe\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2023\/10\/Sauermann-SI-PRO-UI-100-H_2.png\",\"datePublished\":\"2024-10-11T18:31:53+00:00\",\"dateModified\":\"2025-04-01T17:11:46+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/chevrierinstruments.com\/en\/produit\/heated-humidity-probe\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/chevrierinstruments.com\/en\/produit\/heated-humidity-probe\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/chevrierinstruments.com\/en\/produit\/heated-humidity-probe\/#primaryimage\",\"url\":\"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2023\/10\/Sauermann-SI-PRO-UI-100-H_2.png\",\"contentUrl\":\"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2023\/10\/Sauermann-SI-PRO-UI-100-H_2.png\",\"width\":1300,\"height\":1300},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/chevrierinstruments.com\/en\/produit\/heated-humidity-probe\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\/\/chevrierinstruments.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Heated dewpoint &#038; hygrometry probe\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/chevrierinstruments.com\/en\/#website\",\"url\":\"https:\/\/chevrierinstruments.com\/en\/\",\"name\":\"Chevrier Instruments inc.\",\"description\":\"La r\u00e9f\u00e9rence en instruments de mesure\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/chevrierinstruments.com\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Heated dewpoint & hygrometry probe - Chevrier Instruments inc.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/chevrierinstruments.com\/en\/produit\/heated-humidity-probe\/","og_locale":"en_US","og_type":"article","og_title":"Heated dewpoint & hygrometry probe - Chevrier Instruments inc.","og_description":"Si-PRO-U-I-100-H For demanding processes and climate control applications The Si-PRO-U-I-100-H is an interchangeable, heated hygrometry probe for Si-C320 transmitters and it has been designed for being used in environments where there is constant high humidity or rapid oscillanting humidity where the probe\u2019s performance and its tolerance to pollutants are key.","og_url":"https:\/\/chevrierinstruments.com\/en\/produit\/heated-humidity-probe\/","og_site_name":"Chevrier Instruments inc.","article_modified_time":"2025-04-01T17:11:46+00:00","og_image":[{"width":1300,"height":1300,"url":"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2023\/10\/Sauermann-SI-PRO-UI-100-H_2.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/chevrierinstruments.com\/en\/produit\/heated-humidity-probe\/","url":"https:\/\/chevrierinstruments.com\/en\/produit\/heated-humidity-probe\/","name":"Heated dewpoint & hygrometry probe - Chevrier Instruments inc.","isPartOf":{"@id":"https:\/\/chevrierinstruments.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/chevrierinstruments.com\/en\/produit\/heated-humidity-probe\/#primaryimage"},"image":{"@id":"https:\/\/chevrierinstruments.com\/en\/produit\/heated-humidity-probe\/#primaryimage"},"thumbnailUrl":"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2023\/10\/Sauermann-SI-PRO-UI-100-H_2.png","datePublished":"2024-10-11T18:31:53+00:00","dateModified":"2025-04-01T17:11:46+00:00","breadcrumb":{"@id":"https:\/\/chevrierinstruments.com\/en\/produit\/heated-humidity-probe\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/chevrierinstruments.com\/en\/produit\/heated-humidity-probe\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/chevrierinstruments.com\/en\/produit\/heated-humidity-probe\/#primaryimage","url":"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2023\/10\/Sauermann-SI-PRO-UI-100-H_2.png","contentUrl":"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2023\/10\/Sauermann-SI-PRO-UI-100-H_2.png","width":1300,"height":1300},{"@type":"BreadcrumbList","@id":"https:\/\/chevrierinstruments.com\/en\/produit\/heated-humidity-probe\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/chevrierinstruments.com\/en\/"},{"@type":"ListItem","position":2,"name":"Heated dewpoint &#038; hygrometry probe"}]},{"@type":"WebSite","@id":"https:\/\/chevrierinstruments.com\/en\/#website","url":"https:\/\/chevrierinstruments.com\/en\/","name":"Chevrier Instruments inc.","description":"La r\u00e9f\u00e9rence en instruments de mesure","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/chevrierinstruments.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/product\/11973","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/media\/7818"}],"wp:attachment":[{"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/media?parent=11973"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/product_brand?post=11973"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/product_cat?post=11973"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/product_tag?post=11973"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}