{"id":3117,"date":"2023-01-05T20:47:52","date_gmt":"2023-01-05T20:47:52","guid":{"rendered":"https:\/\/chevrier.adgmarketing.com\/produit\/sonde-de-temperature-thermocouple\/"},"modified":"2025-09-04T20:48:08","modified_gmt":"2025-09-04T20:48:08","slug":"sonde-de-temperature-thermocouple","status":"publish","type":"product","link":"https:\/\/chevrierinstruments.com\/en\/produit\/sonde-de-temperature-thermocouple\/","title":{"rendered":"Thermocouple temperature probes"},"content":{"rendered":"<table style=\"width: 66.2671%; height: 3384px;\" width=\"904\">\n<tbody>\n<tr style=\"background-color: #067fb5; height: 24px;\">\n<td style=\"width: 11.4572%; height: 24px;\"><span style=\"color: #ffffff;\"><strong>Reference<\/strong><\/span><\/td>\n<td style=\"width: 21.802%; height: 24px;\"><span style=\"color: #ffffff;\"><strong>Model<\/strong><\/span><\/td>\n<td style=\"width: 65.6285%; height: 24px;\" width=\"600\"><strong><span style=\"color: #ffffff;\">THERMOCOUPLE K PROBES FOR PIPES<\/span><\/strong><\/td>\n<\/tr>\n<tr style=\"height: 66px;\">\n<td style=\"width: 11.4572%; height: 66px;\" width=\"103\">17156<\/td>\n<td style=\"width: 21.802%; height: 66px;\" width=\"201\">SKV 150<\/td>\n<td style=\"width: 65.6285%; height: 66px;\" width=\"600\">Thermocouple K Velcro contact probe, class 1 (-20 to + 90\u00b0C). Fixing with Velcro for duct \u00d8 100mm maximum, with 1.50m cable, miniature male compensated connector.\u00a0\u00a0 (Tr 99% : 50 sec)<\/td>\n<\/tr>\n<tr style=\"height: 66px;\">\n<td style=\"width: 11.4572%; height: 66px;\" width=\"103\">17157<\/td>\n<td style=\"width: 21.802%; height: 66px;\" width=\"201\">SKV 300<\/td>\n<td style=\"width: 65.6285%; height: 66px;\" width=\"600\">Thermocouple K Velcro contact probe, class 1 (-20 to + 90\u00b0C). Fixing with Velcro for duct \u00d8 100mm maximum, with 3m cable, miniature male compensated connector.\u00a0\u00a0 (Tr 99% : 50 sec)<\/td>\n<\/tr>\n<tr style=\"height: 66px;\">\n<td style=\"width: 11.4572%; height: 66px;\" width=\"103\">17159<\/td>\n<td style=\"width: 21.802%; height: 66px;\" width=\"201\">SKV 500<\/td>\n<td style=\"width: 65.6285%; height: 66px;\" width=\"600\">Thermocouple K Velcro contact probe, class 1 (-20 to + 90\u00b0C). Fixing with Velcro for duct \u00d8 100mm maximum, with 5m cable, miniature male compensated connector.\u00a0\u00a0 (Tr 99% : 50 sec)<\/td>\n<\/tr>\n<tr style=\"height: 66px;\">\n<td style=\"width: 11.4572%; height: 66px;\" width=\"103\">22226<\/td>\n<td style=\"width: 21.802%; height: 66px;\" width=\"201\">SKCT<\/td>\n<td style=\"width: 65.6285%; height: 66px;\" width=\"600\">Thermocouple K lamella contact probe, class 1, for duct with diameter from \u00d8 10 to 50 mm (-40 to +150\u00b0C), handle with spring, retractable cable, miniature male compensated connector.\u00a0 (Tr 99% : 15 sec)<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 11.4572%; height: 24px;\" width=\"103\"><\/td>\n<td style=\"width: 21.802%; height: 24px;\" width=\"201\"><\/td>\n<td style=\"width: 65.6285%; height: 24px;\" width=\"600\"><\/td>\n<\/tr>\n<tr style=\"background-color: #067fb5; height: 24px;\">\n<td style=\"width: 11.4572%; height: 24px;\"><span style=\"color: #ffffff;\"><strong>Reference<\/strong><\/span><\/td>\n<td style=\"width: 21.802%; height: 24px;\"><span style=\"color: #ffffff;\"><strong>Model<\/strong><\/span><\/td>\n<td style=\"width: 65.6285%; height: 24px;\"><strong>CONTACT THERMOCOUPLE K PROBES<\/strong><\/td>\n<\/tr>\n<tr style=\"height: 66px;\">\n<td style=\"width: 11.4572%; height: 66px;\" width=\"103\">25729<\/td>\n<td style=\"width: 21.802%; height: 66px;\" width=\"201\">SCPK-150<\/td>\n<td style=\"width: 65.6285%; height: 66px;\" width=\"600\">Thermocouple K contact probe, flat tip, class 1 (-20 to +150\u00b0C). Stainless steel probe \u00d8 4,5 mm, length 150mm with handle, retractable cable, miniature male compensated connector.\u00a0 (Tr 99% : 20 sec)<\/td>\n<\/tr>\n<tr style=\"height: 87px;\">\n<td style=\"width: 11.4572%; height: 87px;\" width=\"103\">24855<\/td>\n<td style=\"width: 21.802%; height: 87px;\" width=\"201\">SCCK-150<\/td>\n<td style=\"width: 65.6285%; height: 87px;\" width=\"600\">SCCK-150 Thermocouple K flat tip contact probe, with copper pellet for small spaces (-20 to +150\u00b0C). \u00d8 6 mm pellet, stainless steel probe \u00d8 4.5 mm, length 150 mm with handle, retractable cable, miniature male compensated connector (Tr 99% : 30 sec)<\/td>\n<\/tr>\n<tr style=\"height: 66px;\">\n<td style=\"width: 11.4572%; height: 66px;\" width=\"103\">24648<\/td>\n<td style=\"width: 21.802%; height: 66px;\" width=\"201\">SCLK-150<\/td>\n<td style=\"width: 65.6285%; height: 66px;\" width=\"600\">Thermocouple K lamella contact probe, class 1 (-40 to +250\u00b0C). Stainless steel probe \u00d8 6 mm, length 150mm with handle, retractable cable, miniature male compensated connector.\u00a0 (Tr 99% :\u00a0 5sec)<\/td>\n<\/tr>\n<tr style=\"height: 87px;\">\n<td style=\"width: 11.4572%; height: 87px;\" width=\"103\">24649<\/td>\n<td style=\"width: 21.802%; height: 87px;\" width=\"201\">SCLCK-150<\/td>\n<td style=\"width: 65.6285%; height: 87px;\" width=\"600\">Thermocouple K lamella contact probe, bent at 90\u00b0, class 1 (-40 to +250\u00b0C). Stainless steel probe \u00d8 6 mm, length 150mm, bent at 90\u00b0C on 50mm, with handle, retractable cable, miniature male compensated connector.\u00a0 (Tr 99% :\u00a0 5sec)<\/td>\n<\/tr>\n<tr style=\"height: 87px;\">\n<td style=\"width: 11.4572%; height: 87px;\" width=\"103\">24681<\/td>\n<td style=\"width: 21.802%; height: 87px;\" width=\"201\">SCLK-HT<\/td>\n<td style=\"width: 65.6285%; height: 87px;\" width=\"600\">SCLK-HT Thermocouple K lamella contact probe, high temperature (-50 to +800\u00b0C). Lamella \u00d8 27 m, stainless steel probe \u00d8 20 mm, length 200mm with handle, straight cable length 1m and miniature male compensated connector (Tr 99% : 5 sec)<\/td>\n<\/tr>\n<tr style=\"height: 66px;\">\n<td style=\"width: 11.4572%; height: 66px;\" width=\"103\">24716<\/td>\n<td style=\"width: 21.802%; height: 66px;\" width=\"201\">SCLAIK<\/td>\n<td style=\"width: 65.6285%; height: 66px;\" width=\"600\">SCLAIK thermocouple K probe, magnet contact lamella (-40 to +250\u00b0C) Dimensions 27x32 mm, height 34 mm, straight cable length 1 m, miniature male compensated connector (Tr 99% : 5 sec)<\/td>\n<\/tr>\n<tr style=\"height: 87px;\">\n<td style=\"width: 11.4572%; height: 87px;\" width=\"103\">21254<\/td>\n<td style=\"width: 21.802%; height: 87px;\" width=\"201\">SFCSMK<\/td>\n<td style=\"width: 65.6285%; height: 87px;\" width=\"600\">Thermocouple K temperature probe for surface measurement on moving parts (0 to +400 \u00b0C). Contact element made of aluminium, on wheel, with handle, retractable cable, miniature male compensated connector (Tr 99% : 4 sec)<\/td>\n<\/tr>\n<tr style=\"height: 87px;\">\n<td style=\"width: 11.4572%; height: 87px;\" width=\"103\">25111<\/td>\n<td style=\"width: 21.802%; height: 87px;\" width=\"201\">SCRK-150<\/td>\n<td style=\"width: 65.6285%; height: 87px;\" width=\"600\">SCRK-150 Thermocouple K contact probe: contact for small space. Measuring range from -20 to +150\u00b0C. Spring-wired contact tip. Stainless steel probe \u00d8 7 mm, length 150 mm, with handle, retractable cable, miniature male compensated connector (Tr 99% : 5 sec)<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 11.4572%; height: 24px;\" width=\"103\"><\/td>\n<td style=\"width: 21.802%; height: 24px;\" width=\"201\"><\/td>\n<td style=\"width: 65.6285%; height: 24px;\" width=\"600\"><\/td>\n<\/tr>\n<tr style=\"background-color: #067fb5; height: 24px;\">\n<td style=\"width: 11.4572%; height: 24px;\"><span style=\"color: #ffffff;\"><strong>Reference<\/strong><\/span><\/td>\n<td style=\"width: 21.802%; height: 24px;\"><span style=\"color: #ffffff;\"><strong>Model<\/strong><\/span><\/td>\n<td style=\"width: 65.6285%; height: 24px;\"><strong><span style=\"color: #ffffff;\">AMBIENT THERMOCOUPLE K PROBES<\/span><\/strong><\/td>\n<\/tr>\n<tr style=\"height: 87px;\">\n<td style=\"width: 11.4572%; height: 87px;\" width=\"103\">17155<\/td>\n<td style=\"width: 21.802%; height: 87px;\" width=\"201\">SKA-110<\/td>\n<td style=\"width: 65.6285%; height: 87px;\" width=\"600\">Thermocouple K ambient probe, class 1 (-40 to +80\u00b0C) Stainless steel perforated probe \u00d8 4,5 mm, length 110 mm, direct output on miniature male compensated connector, without handle and without cable. (Tr 99% : 50 sec)<\/td>\n<\/tr>\n<tr style=\"height: 66px;\">\n<td style=\"width: 11.4572%; height: 66px;\" width=\"103\">24646<\/td>\n<td style=\"width: 21.802%; height: 66px;\" width=\"201\">SAK-150<\/td>\n<td style=\"width: 65.6285%; height: 66px;\" width=\"600\">Thermocouple K ambient probe, class 1 (-40 to +250\u00b0C). Stainless steel perforated probe \u00d8 4.5 mm, length 150mm with handle, retractable cable and miniature male compensated connector.\u00a0 (Tr 99% : 50 sec)<\/td>\n<\/tr>\n<tr style=\"height: 66px;\">\n<td style=\"width: 11.4572%; height: 66px;\" width=\"103\">24816<\/td>\n<td style=\"width: 21.802%; height: 66px;\" width=\"201\">SAK-05<\/td>\n<td style=\"width: 65.6285%; height: 66px;\" width=\"600\">Thermocouple K wire probe, class 1, (-40 to +250\u00b0C). Visible welding, isolated PTFE cable length 0.5 m, output on miniature male compensated connector. (Tr 99% : 3 sec)<\/td>\n<\/tr>\n<tr style=\"height: 66px;\">\n<td style=\"width: 11.4572%; height: 66px;\" width=\"103\">24817<\/td>\n<td style=\"width: 21.802%; height: 66px;\" width=\"201\">SAK-1<\/td>\n<td style=\"width: 65.6285%; height: 66px;\" width=\"600\">Thermocouple K wire probe, class 1, (-40 to +250\u00b0C). Visible welding, isolated PTFE cable length 1m, output on miniature male compensated connector. (Tr 99% : 3 sec)<\/td>\n<\/tr>\n<tr style=\"height: 66px;\">\n<td style=\"width: 11.4572%; height: 66px;\" width=\"103\">24818<\/td>\n<td style=\"width: 21.802%; height: 66px;\" width=\"201\">SAK-2<\/td>\n<td style=\"width: 65.6285%; height: 66px;\" width=\"600\">Thermocouple K wire probe, class 1, (-40 to +250\u00b0C). Visible welding, isolated PTFE cable length 2m, output on miniature male compensated connector. (Tr 99% : 3 sec)<\/td>\n<\/tr>\n<tr style=\"height: 66px;\">\n<td style=\"width: 11.4572%; height: 66px;\" width=\"103\">24819<\/td>\n<td style=\"width: 21.802%; height: 66px;\" width=\"201\">SAK-5<\/td>\n<td style=\"width: 65.6285%; height: 66px;\" width=\"600\">Thermocouple K wire probe, class 1, (-40 to +250\u00b0C). Visible welding, isolated PTFE cable length 5m, output on miniature male compensated connector. (Tr 99% : 3 sec)<\/td>\n<\/tr>\n<tr style=\"height: 66px;\">\n<td style=\"width: 11.4572%; height: 66px;\" width=\"103\">24820<\/td>\n<td style=\"width: 21.802%; height: 66px;\" width=\"201\">SAK-10<\/td>\n<td style=\"width: 65.6285%; height: 66px;\" width=\"600\">Thermocouple K wire probe, class 1, (-40 to +250\u00b0C). Visible welding, isolated PTFE cable length 10m, output on miniature male compensated connector. (Tr 99% : 3 sec)<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 11.4572%; height: 24px;\" width=\"103\"><\/td>\n<td style=\"width: 21.802%; height: 24px;\" width=\"201\"><\/td>\n<td style=\"width: 65.6285%; height: 24px;\" width=\"600\"><\/td>\n<\/tr>\n<tr style=\"background-color: #067fb5; height: 24px;\">\n<td style=\"width: 11.4572%; height: 24px;\"><span style=\"color: #ffffff;\"><strong>Reference<\/strong><\/span><\/td>\n<td style=\"width: 21.802%; height: 24px;\"><span style=\"color: #ffffff;\"><strong>Model<\/strong><\/span><\/td>\n<td style=\"width: 65.6285%; height: 24px;\"><strong><span style=\"color: #ffffff;\">PENETRATION THERMOCOUPLE K PROBES<\/span><\/strong><\/td>\n<\/tr>\n<tr style=\"height: 66px;\">\n<td style=\"width: 11.4572%; height: 66px;\" width=\"103\">24650<\/td>\n<td style=\"width: 21.802%; height: 66px;\" width=\"201\">SPK 150<\/td>\n<td style=\"width: 65.6285%; height: 66px;\" width=\"600\">Thermocouple K penetration probe, class 1 (-40 to +250\u00b0C). Stainless steel probe \u00d8 4.5mm, sharp tip, length 150mm, with handle, retractable cable, miniature male compensated connector. (Tr 99% : 30 sec).<\/td>\n<\/tr>\n<tr style=\"height: 66px;\">\n<td style=\"width: 11.4572%; height: 66px;\" width=\"103\">24823<\/td>\n<td style=\"width: 21.802%; height: 66px;\" width=\"201\">SPK 300<\/td>\n<td style=\"width: 65.6285%; height: 66px;\" width=\"600\">Thermocouple K penetration probe (-40 to +250\u00b0C). Stainless steel probe \u00d8 4,5 mm with sharp tip, length 300 mm, with handle, retractable cab le and miniature male compensated connector (Tr 99% : 35 sec).<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 11.4572%; height: 24px;\" width=\"103\"><\/td>\n<td style=\"width: 21.802%; height: 24px;\" width=\"201\"><\/td>\n<td style=\"width: 65.6285%; height: 24px;\" width=\"600\"><\/td>\n<\/tr>\n<tr style=\"background-color: #067fb5; height: 24px;\">\n<td style=\"width: 11.4572%; height: 24px;\"><span style=\"color: #ffffff;\"><strong>Reference<\/strong><\/span><\/td>\n<td style=\"width: 21.802%; height: 24px;\"><span style=\"color: #ffffff;\"><strong>Model<\/strong><\/span><\/td>\n<td style=\"width: 65.6285%; height: 24px;\"><span style=\"color: #ffffff;\"><strong>THERMOCOUPLE K PROBES FOR COMPOST<\/strong><\/span><\/td>\n<\/tr>\n<tr style=\"height: 87px;\">\n<td style=\"width: 11.4572%; height: 87px;\" width=\"103\">17160<\/td>\n<td style=\"width: 21.802%; height: 87px;\" width=\"201\">SKP 1000<\/td>\n<td style=\"width: 65.6285%; height: 87px;\" width=\"600\">Thermocouple K probe, class 1, ( -20 +150\u00b0C) stainless steel protective sheath \u00d8 16 x 2 mm, length 1000 mm with sharp tip. T-shape handle, 2 x 150 mm, diameter 21,3 mm. Output on retractable cable length 1.80 m with miniature male compensated connector\u00a0 (Tr 99% : 165 sec).<\/td>\n<\/tr>\n<tr style=\"height: 87px;\">\n<td style=\"width: 11.4572%; height: 87px;\" width=\"103\">17161<\/td>\n<td style=\"width: 21.802%; height: 87px;\" width=\"201\">SKP 1500<\/td>\n<td style=\"width: 65.6285%; height: 87px;\" width=\"600\">Thermocouple K probe, class 1, ( -20 +150\u00b0C) stainless steel protective sheath \u00d8 16 x 2 mm, length 1500 mm with sharp tip, T-shape handle 2 x 150 mm, diameter 21,3 mm. Output on retractable cable length 1.80 m with miniature male compensated connector\u00a0 (Tr 99% : 165 sec).<\/td>\n<\/tr>\n<tr style=\"height: 87px;\">\n<td style=\"width: 11.4572%; height: 87px;\" width=\"103\">17163<\/td>\n<td style=\"width: 21.802%; height: 87px;\" width=\"201\">SKP 2000<\/td>\n<td style=\"width: 65.6285%; height: 87px;\" width=\"600\">Thermocouple K probe, class 1, ( -20 +150\u00b0C) stainless steel protective sheath \u00d8 16 x 2 mm, length 2000 mm with sharp tip, T-shape handle 2 x 150 mm, diameter 21.3 mm. Output on retractable cable length 1.80 m with miniature male compensated connector\u00a0 (Tr 99% : 165 sec).<\/td>\n<\/tr>\n<tr style=\"height: 170px;\">\n<td style=\"width: 11.4572%; height: 170px;\" width=\"103\">25820<\/td>\n<td style=\"width: 21.802%; height: 170px;\" width=\"201\">SKP1000B<\/td>\n<td style=\"width: 65.6285%; height: 170px;\" width=\"600\">SKP1000-B Thermocouple K probe, class 1, ( -20 +150\u00b0C) stainless steel 316L protective sheath \u00d8 16 x 2 mm, length 1000 mm with sharp tip. T-shape handle, 2 x 150 mm, diameter 21,3 mm. IP65 housing with transparent cover, EPDM seal and machined foam for Kistock KTT 220 or 320 and RF (supplied without the recorder). Housing 170x140x95 mm mounted horizontally on the probe. Output on cable length 20 cm with miniature male compensated connector inside the housing (Tr 99%: 165 sec)<\/td>\n<\/tr>\n<tr style=\"height: 170px;\">\n<td style=\"width: 11.4572%; height: 170px;\" width=\"103\">25821<\/td>\n<td style=\"width: 21.802%; height: 170px;\" width=\"201\">SKP1500B<\/td>\n<td style=\"width: 65.6285%; height: 170px;\" width=\"600\">SKP1500-B Thermocouple K probe, class 1, ( -20 +150\u00b0C) stainless steel 316L protective sheath \u00d8 16 x 2 mm, length 1500 mm with sharp tip. T-shape handle, 2 x 150 mm, diameter 21,3 mm. IP65 housing with transparent cover, EPDM seal and machined foam for Kistock KTT 220 or 320 and RF (supplied without the recorder). Housing 170x140x95 mm mounted horizontally on the probe. Output on cable length 20 cm with miniature male compensated connector inside the housing (Tr 99%: 165 sec)<\/td>\n<\/tr>\n<tr style=\"height: 170px;\">\n<td style=\"width: 11.4572%; height: 170px;\" width=\"103\">25822<\/td>\n<td style=\"width: 21.802%; height: 170px;\" width=\"201\">SKP2000B<\/td>\n<td style=\"width: 65.6285%; height: 170px;\" width=\"600\">SKP2000-B Thermocouple K probe, class 1, ( -20 +150\u00b0C) stainless steel 316L protective sheath \u00d8 16 x 2 mm, length 2000 mm with sharp tip. T-shape handle, 2 x 150 mm, diameter 21,3 mm. IP65 housing with transparent cover, EPDM seal and machined foam for Kistock KTT 220 or 320 and RF (supplied without the recorder). Housing 170x140x95 mm mounted horizontally on the probe. Output on cable length 20 cm with miniature male compensated connector inside the housing (Tr 99%: 165 sec)<\/td>\n<\/tr>\n<tr style=\"height: 87px;\">\n<td style=\"width: 11.4572%; height: 87px;\" width=\"103\">14809<\/td>\n<td style=\"width: 21.802%; height: 87px;\" width=\"201\">KSP S+M<\/td>\n<td style=\"width: 65.6285%; height: 87px;\" width=\"600\">Supply and mounting of the galvanised plate type KSP on the compost probes SKP1000\/1500\/2000 for fixing the kistocks or the magnetic protection shells of the thermometers (should be ordered with the SKP probe).<\/td>\n<\/tr>\n<tr style=\"height: 87px;\">\n<td style=\"width: 11.4572%; height: 87px;\" width=\"103\">24829<\/td>\n<td style=\"width: 21.802%; height: 87px;\" width=\"201\">KIT-KSP<\/td>\n<td style=\"width: 65.6285%; height: 87px;\" width=\"600\">Kit including galva plate (KSP) for compost probe. Fixing with anti-theft system support (KAV from Kistock range), or with magnet protective cover and mounting accessories. MOUNTING DONE BY THE USER (not at our factory)<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 11.4572%; height: 24px;\" width=\"103\"><\/td>\n<td style=\"width: 21.802%; height: 24px;\" width=\"201\"><\/td>\n<td style=\"width: 65.6285%; height: 24px;\" width=\"600\"><\/td>\n<\/tr>\n<tr style=\"background-color: #067fb5; height: 24px;\">\n<td style=\"width: 11.4572%; height: 24px;\"><span style=\"color: #ffffff;\"><strong>Reference<\/strong><\/span><\/td>\n<td style=\"width: 21.802%; height: 24px;\"><span style=\"color: #ffffff;\"><strong>Model<\/strong><\/span><\/td>\n<td style=\"width: 65.6285%; height: 24px;\"><strong><span style=\"color: #ffffff;\">IMMERSION THERMOCOUPLE PROBES<\/span><\/strong><\/td>\n<\/tr>\n<tr style=\"height: 66px;\">\n<td style=\"width: 11.4572%; height: 66px;\" width=\"103\">24641<\/td>\n<td style=\"width: 21.802%; height: 66px;\" width=\"201\">SIK 150<\/td>\n<td style=\"width: 65.6285%; height: 66px;\" width=\"600\">Thermocouple K immersion probe, (-40 to +250\u00b0C). Stainless steel probe \u00d8 4.5 mm, length 150mm with handle, retractable cable and miniature male compensated connector. (Tr 99% : 35 sec).<\/td>\n<\/tr>\n<tr style=\"height: 66px;\">\n<td style=\"width: 11.4572%; height: 66px;\" width=\"103\">24642<\/td>\n<td style=\"width: 21.802%; height: 66px;\" width=\"201\">SIK 250<\/td>\n<td style=\"width: 65.6285%; height: 66px;\" width=\"600\">Thermocouple K immersion probe, class 1 (-40 to +250\u00b0C). Stainless steel probe \u00d8 4.5 mm, length 250mm with handle, retractable cable and miniature male compensated connector. (Tr 99% : 35 sec).<\/td>\n<\/tr>\n<tr style=\"height: 66px;\">\n<td style=\"width: 11.4572%; height: 66px;\" width=\"103\">24644<\/td>\n<td style=\"width: 21.802%; height: 66px;\" width=\"201\">SIK 500 HT<\/td>\n<td style=\"width: 65.6285%; height: 66px;\" width=\"600\">Thermocouple K immersion probe, class 1 (-40 to +1000\u00b0C). Inconel probe \u00d8 6 mm, length 500mm with handle, retractable cable and miniature male compensated connector. (Tr 99% : 115 sec).<\/td>\n<\/tr>\n<tr style=\"height: 66px;\">\n<td style=\"width: 11.4572%; height: 66px;\" width=\"103\">24645<\/td>\n<td style=\"width: 21.802%; height: 66px;\" width=\"201\">SIK 1000 HT<\/td>\n<td style=\"width: 65.6285%; height: 66px;\" width=\"600\">Thermocouple K immersion probe, class 1 (-40 to +1000\u00b0C). Inconel probe \u00d8 6 mm, length 1000mm with handle, retractable cable and miniature male compensated connector. (Tr 99% : 115 sec).<\/td>\n<\/tr>\n<tr style=\"height: 66px;\">\n<td style=\"width: 11.4572%; height: 66px;\" width=\"103\">24830<\/td>\n<td style=\"width: 21.802%; height: 66px;\" width=\"201\">SIS 1000\u00a0 HT<\/td>\n<td style=\"width: 65.6285%; height: 66px;\" width=\"600\">Thermocouple S immersion probe, very high temperature (0 to + 1400\u00b0C). Ceramic probe \u00d8 8 mm, length 1000 mm with handle, straight cable and miniature male compensated connector.<\/td>\n<\/tr>\n<tr style=\"height: 87px;\">\n<td style=\"width: 11.4572%; height: 87px;\" width=\"103\">24831<\/td>\n<td style=\"width: 21.802%; height: 87px;\" width=\"201\">SIT 300 BT<\/td>\n<td style=\"width: 65.6285%; height: 87px;\" width=\"600\">Thermocouple T immersion probe, very Low temperature (-196 to + 50\u00b0). Stainless steel probe \u00d8 1.5 mm, length 300 mm with handle, retractable cable and miniature male compensated connector\u00a0 (Tr 99% : 2 sec).<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 11.4572%; height: 24px;\" width=\"103\"><\/td>\n<td style=\"width: 21.802%; height: 24px;\" width=\"201\"><\/td>\n<td style=\"width: 65.6285%; height: 24px;\" width=\"600\"><\/td>\n<\/tr>\n<tr style=\"background-color: #067fb5;\">\n<td style=\"width: 11.4572%; height: 24px;\"><span style=\"color: #ffffff;\"><strong>Reference<\/strong><\/span><\/td>\n<td style=\"width: 21.802%; height: 24px;\"><span style=\"color: #ffffff;\"><strong>Model<\/strong><\/span><\/td>\n<td style=\"width: 65.6285%; height: 24px;\"><span style=\"color: #ffffff;\"><strong>EXTENSIONS FOR THERMOCOUPLE K PROBES<\/strong><\/span><\/td>\n<\/tr>\n<tr style=\"height: 66px;\">\n<td style=\"width: 11.4572%; height: 66px;\" width=\"103\">24834<\/td>\n<td style=\"width: 21.802%; height: 66px;\" width=\"201\">RTCK-150<\/td>\n<td style=\"width: 65.6285%; height: 66px;\" width=\"600\">Extension cable made of PVC, armoured, Thermocouple K, class 1. Length 1.50 m for temperature probe with miniature male\/female compensated connector. Temperature : 0 to 100 \u00b0C.<\/td>\n<\/tr>\n<tr style=\"height: 66px;\">\n<td style=\"width: 11.4572%; height: 66px;\" width=\"103\">24835<\/td>\n<td style=\"width: 21.802%; height: 66px;\" width=\"201\">RTCK-300<\/td>\n<td style=\"width: 65.6285%; height: 66px;\" width=\"600\">Extension cable made of PVC, armoured, Thermocouple K, class 1. Length 3 m for temperature probe with miniature male\/female compensated connector. Temperature : 0 to 100 \u00b0C.<\/td>\n<\/tr>\n<tr style=\"height: 66px;\">\n<td style=\"width: 11.4572%; height: 66px;\" width=\"103\">24836<\/td>\n<td style=\"width: 21.802%; height: 66px;\" width=\"201\">RTCK-500<\/td>\n<td style=\"width: 65.6285%; height: 66px;\" width=\"600\">Extension cable made of PVC, armoured, Thermocouple K, class 1. Length 5 m for temperature probe with miniature male\/female compensated connector. Temperature : 0 to 100 \u00b0C.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<h2 class=\"page__title\">Thermocouple temperature probes<\/h2>\n<p>For thermometers and data loggers with miniature thermocouple plug input<\/p>\n","protected":false},"featured_media":3022,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[510,1131,361,47,56],"product_tag":[538],"class_list":{"0":"post-3117","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-accessories","7":"product_cat-for-thermometers","8":"product_cat-heating-refrigeration-air-conditioning","9":"product_cat-air-conditioning","10":"product_cat-temperature-en","11":"product_tag-temperature-probe","13":"first","14":"instock","15":"shipping-taxable","16":"product-type-simple"},"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Thermocouple temperature probes - Chevrier Instruments inc.<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/chevrierinstruments.com\/en\/produit\/sonde-de-temperature-thermocouple\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Thermocouple temperature probes - Chevrier Instruments inc.\" \/>\n<meta property=\"og:description\" content=\"Thermocouple temperature probes For thermometers and data loggers with miniature thermocouple plug input\" \/>\n<meta property=\"og:url\" content=\"https:\/\/chevrierinstruments.com\/en\/produit\/sonde-de-temperature-thermocouple\/\" \/>\n<meta property=\"og:site_name\" content=\"Chevrier Instruments inc.\" \/>\n<meta property=\"article:modified_time\" content=\"2025-09-04T20:48:08+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2023\/01\/sondes-thermo_0.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1300\" \/>\n\t<meta property=\"og:image:height\" content=\"1300\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"8 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/chevrierinstruments.com\/en\/produit\/sonde-de-temperature-thermocouple\/\",\"url\":\"https:\/\/chevrierinstruments.com\/en\/produit\/sonde-de-temperature-thermocouple\/\",\"name\":\"Thermocouple temperature probes - Chevrier Instruments inc.\",\"isPartOf\":{\"@id\":\"https:\/\/chevrierinstruments.com\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/chevrierinstruments.com\/en\/produit\/sonde-de-temperature-thermocouple\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/chevrierinstruments.com\/en\/produit\/sonde-de-temperature-thermocouple\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2023\/01\/sondes-thermo_0.jpg\",\"datePublished\":\"2023-01-05T20:47:52+00:00\",\"dateModified\":\"2025-09-04T20:48:08+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/chevrierinstruments.com\/en\/produit\/sonde-de-temperature-thermocouple\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/chevrierinstruments.com\/en\/produit\/sonde-de-temperature-thermocouple\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/chevrierinstruments.com\/en\/produit\/sonde-de-temperature-thermocouple\/#primaryimage\",\"url\":\"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2023\/01\/sondes-thermo_0.jpg\",\"contentUrl\":\"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2023\/01\/sondes-thermo_0.jpg\",\"width\":1300,\"height\":1300,\"caption\":\"Sondes thermocouples\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/chevrierinstruments.com\/en\/produit\/sonde-de-temperature-thermocouple\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\/\/chevrierinstruments.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Thermocouple temperature probes\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/chevrierinstruments.com\/en\/#website\",\"url\":\"https:\/\/chevrierinstruments.com\/en\/\",\"name\":\"Chevrier Instruments inc.\",\"description\":\"La r\u00e9f\u00e9rence en instruments de mesure\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/chevrierinstruments.com\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Thermocouple temperature probes - Chevrier Instruments inc.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/chevrierinstruments.com\/en\/produit\/sonde-de-temperature-thermocouple\/","og_locale":"en_US","og_type":"article","og_title":"Thermocouple temperature probes - Chevrier Instruments inc.","og_description":"Thermocouple temperature probes For thermometers and data loggers with miniature thermocouple plug input","og_url":"https:\/\/chevrierinstruments.com\/en\/produit\/sonde-de-temperature-thermocouple\/","og_site_name":"Chevrier Instruments inc.","article_modified_time":"2025-09-04T20:48:08+00:00","og_image":[{"width":1300,"height":1300,"url":"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2023\/01\/sondes-thermo_0.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"8 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/chevrierinstruments.com\/en\/produit\/sonde-de-temperature-thermocouple\/","url":"https:\/\/chevrierinstruments.com\/en\/produit\/sonde-de-temperature-thermocouple\/","name":"Thermocouple temperature probes - Chevrier Instruments inc.","isPartOf":{"@id":"https:\/\/chevrierinstruments.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/chevrierinstruments.com\/en\/produit\/sonde-de-temperature-thermocouple\/#primaryimage"},"image":{"@id":"https:\/\/chevrierinstruments.com\/en\/produit\/sonde-de-temperature-thermocouple\/#primaryimage"},"thumbnailUrl":"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2023\/01\/sondes-thermo_0.jpg","datePublished":"2023-01-05T20:47:52+00:00","dateModified":"2025-09-04T20:48:08+00:00","breadcrumb":{"@id":"https:\/\/chevrierinstruments.com\/en\/produit\/sonde-de-temperature-thermocouple\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/chevrierinstruments.com\/en\/produit\/sonde-de-temperature-thermocouple\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/chevrierinstruments.com\/en\/produit\/sonde-de-temperature-thermocouple\/#primaryimage","url":"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2023\/01\/sondes-thermo_0.jpg","contentUrl":"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2023\/01\/sondes-thermo_0.jpg","width":1300,"height":1300,"caption":"Sondes thermocouples"},{"@type":"BreadcrumbList","@id":"https:\/\/chevrierinstruments.com\/en\/produit\/sonde-de-temperature-thermocouple\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/chevrierinstruments.com\/en\/"},{"@type":"ListItem","position":2,"name":"Thermocouple temperature probes"}]},{"@type":"WebSite","@id":"https:\/\/chevrierinstruments.com\/en\/#website","url":"https:\/\/chevrierinstruments.com\/en\/","name":"Chevrier Instruments inc.","description":"La r\u00e9f\u00e9rence en instruments de mesure","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/chevrierinstruments.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/product\/3117","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/media\/3022"}],"wp:attachment":[{"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/media?parent=3117"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/product_brand?post=3117"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/product_cat?post=3117"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/product_tag?post=3117"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}