{"id":7038,"date":"2022-05-17T19:16:23","date_gmt":"2022-05-17T19:16:23","guid":{"rendered":"https:\/\/chevrierinstruments.com\/produit\/pince-multimetre-a-affichage-distant-trms-ca-dc-avec-iflex-381\/"},"modified":"2024-07-30T19:31:23","modified_gmt":"2024-07-30T19:31:23","slug":"pince-multimetre-a-affichage-distant-trms-ca-dc-avec-iflex-381","status":"publish","type":"product","link":"https:\/\/chevrierinstruments.com\/en\/produit\/pince-multimetre-a-affichage-distant-trms-ca-dc-avec-iflex-381\/","title":{"rendered":"Pince multim\u00e8tre \u00e0 affichage distant TRMS CA\/DC avec iFlex\u00ae"},"content":{"rendered":"<h4 class=\"features-title\">Key features<\/h4>\n<div id=\"keyfeature_content\">\n<ul>\n<li>Wireless technology allows the display to be carried up to 30 ft. away from the point of measurement with measurement accuracy<\/li>\n<li>Removable magnetic display can be mounted where it is easily seen<\/li>\n<li>iFlex\u00ae Flexible Current Probe expands the measurement range to 2500 A AC<\/li>\n<li>CAT IV 600 V, CAT III 1000 V<\/li>\n<\/ul>\n<\/div>\n<p>The iFlex\u00ae Flexible Current Probe (included) expands the measurement range to 2500 A AC while providing increased display flexibility. With a cord that runs 6 feet, you can finally measure those tight spaces, awkward sized conductors and disorganized wires.<\/p>\n<h4>Other key features<\/h4>\n<ul>\n<li>Integrated low pass filter and state-of-the-art signal processing allows for use in noisy electrical environments while providing stable readings<\/li>\n<li>Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it<\/li>\n<li>Ergonomic design fits in your hand and can be used while wearing protective equipment<\/li>\n<li>Radio transmitter automatically sets the correct measurement range so you do not need to change the switch positions while taking a measurement<\/li>\n<li>Three-year warranty<\/li>\n<\/ul>\n<p><strong>Safety Conformance<\/strong>: IEC\/EN 61010-1:2001, 1000V CAT III, 600V CAT IV<\/p>\n<div id=\"keyfeature_content\" data-readmore=\"\" aria-expanded=\"true\">\n<div id=\"overview-grid\">\n<div id=\"fluke-product-display-overview\">\n<div id=\"overview_content\">\n<table style=\"border-color: #b3a89f;\" border=\"1\">\n<tbody>\n<tr class=\"head\">\n<td style=\"background-color: #b3a89f;\" colspan=\"5\">\n<h4><strong>Electrical Specifications<\/strong><\/h4>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">AC Current via Jaw<\/td>\n<\/tr>\n<tr>\n<td>Range<\/td>\n<td colspan=\"4\">999.9 A<\/td>\n<\/tr>\n<tr>\n<td>Resolution<\/td>\n<td colspan=\"4\">0.1 A<\/td>\n<\/tr>\n<tr>\n<td>Accuracy<\/td>\n<td colspan=\"4\">2% \u00b1 5 digits (10-100 Hz)<br \/>\n5% \u00b1 5 digits (100-500 Hz)<\/td>\n<\/tr>\n<tr>\n<td>Crest Factor (50\/60 Hz)<\/td>\n<td colspan=\"4\">3 @ 500 A<br \/>\n2.5 @ 600 A<br \/>\n1.42 @ 1000 A<br \/>\nAdd 2% for C.F. &gt; 2<\/td>\n<\/tr>\n<tr class=\"head\">\n<td style=\"background-color: #b3a89f;\" colspan=\"5\"><strong>AC Current via Flexible Current Probe<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Range<\/td>\n<td colspan=\"4\">999.9 A \/ 2500 A (45 Hz \u2013 500 Hz)<\/td>\n<\/tr>\n<tr>\n<td>Resolution<\/td>\n<td colspan=\"4\">0.1 A \/ 1 A<\/td>\n<\/tr>\n<tr>\n<td>Accuracy<\/td>\n<td colspan=\"4\">3% \u00b1 5 digits<\/td>\n<\/tr>\n<tr>\n<td>Crest Factor (50\/60 Hz)<\/td>\n<td colspan=\"4\">3.0 at 1100 A<br \/>\n2.5 at 1400 A<br \/>\n1.42 at 2500 A<br \/>\nAdd 2% for C.F. &gt; 2<\/td>\n<\/tr>\n<tr class=\"head\">\n<td style=\"background-color: #b3a89f;\" colspan=\"5\"><strong>Position Sensitivity<\/strong><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\"><img decoding=\"async\" src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/37x_position_sens_100x181.png\" alt=\"Flexible current probe\" \/><\/td>\n<td colspan=\"4\"><b>Distance from Optimum<\/b><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><b>i2500-10 Flex<\/b><\/td>\n<td><b>i2500-18 Flex<\/b><\/td>\n<td><b>Error<\/b><\/td>\n<\/tr>\n<tr>\n<td><b>A<\/b><\/td>\n<td>0.5 in (12.7 mm)<\/td>\n<td>1.4 in (35.6 mm)<\/td>\n<td>\u00b10.5%<\/td>\n<\/tr>\n<tr>\n<td><b>B<\/b><\/td>\n<td>0.8 in (20.3 mm)<\/td>\n<td>2.0 in (50.8 mm)<\/td>\n<td>\u00b11.0%<\/td>\n<\/tr>\n<tr>\n<td><b>C<\/b><\/td>\n<td>1.4 in (35.6 mm)<\/td>\n<td>2.5 in (63.5 mm)<\/td>\n<td>\u00b12.0%<\/td>\n<\/tr>\n<tr>\n<td class=\"nobold\" colspan=\"5\">Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.<\/td>\n<\/tr>\n<tr class=\"head\">\n<td style=\"background-color: #b3a89f;\" colspan=\"5\"><strong>DC Current<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Range<\/td>\n<td colspan=\"4\">999.9 A<\/td>\n<\/tr>\n<tr>\n<td>Resolution<\/td>\n<td colspan=\"4\">0.1 A<\/td>\n<\/tr>\n<tr>\n<td>Accuracy<\/td>\n<td colspan=\"4\">2% \u00b1 5 digits<\/td>\n<\/tr>\n<tr class=\"head\">\n<td style=\"background-color: #b3a89f;\" colspan=\"5\"><strong>AC Voltage<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Range<\/td>\n<td colspan=\"4\">600 V \/1000 V<\/td>\n<\/tr>\n<tr>\n<td>Resolution<\/td>\n<td colspan=\"4\">0.1 V \/ 1 V<\/td>\n<\/tr>\n<tr>\n<td>Accuracy<\/td>\n<td colspan=\"4\">1.5% \u00b1 5 digits (20 \u2013 500 Hz)<\/td>\n<\/tr>\n<tr class=\"head\">\n<td style=\"background-color: #b3a89f;\" colspan=\"5\"><strong>DC Voltage<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Range<\/td>\n<td colspan=\"4\">600.0 V \/1000 V<\/td>\n<\/tr>\n<tr>\n<td>Resolution<\/td>\n<td colspan=\"4\">0.1 V \/ 1 V<\/td>\n<\/tr>\n<tr>\n<td>Accuracy<\/td>\n<td colspan=\"4\">1% \u00b1 5 digits<\/td>\n<\/tr>\n<tr class=\"head\">\n<td style=\"background-color: #b3a89f;\" colspan=\"5\"><strong>Frequency \u2013 Via Jaw<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Range<\/td>\n<td colspan=\"4\">5.0 \u2013 500.0 Hz<\/td>\n<\/tr>\n<tr>\n<td>Resolution<\/td>\n<td colspan=\"4\">0.1 Hz<\/td>\n<\/tr>\n<tr>\n<td>Accuracy<\/td>\n<td colspan=\"4\">0.5% \u00b1 5 digits<\/td>\n<\/tr>\n<tr>\n<td>Trigger Level<\/td>\n<td colspan=\"4\">5 \u2013 10 Hz, \u2265 10 A<br \/>\n10 \u2013 100 Hz, \u2265 5 A<br \/>\n100 \u2013 500 Hz, \u2265 10 A<\/td>\n<\/tr>\n<tr class=\"head\">\n<td style=\"background-color: #b3a89f;\" colspan=\"5\"><strong>Frequency via Flexible Current Probe<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Range<\/td>\n<td colspan=\"4\">5.0 to 500.0 Hz<\/td>\n<\/tr>\n<tr>\n<td>Resolution<\/td>\n<td colspan=\"4\">0.1 Hz<\/td>\n<\/tr>\n<tr>\n<td>Accuracy<\/td>\n<td colspan=\"4\">0.5% \u00b1 5 digits<\/td>\n<\/tr>\n<tr>\n<td>Trigger Level<\/td>\n<td colspan=\"4\">5 to 20 Hz, \u2265 25 A<br \/>\n20 to 100 Hz, \u2265 20 A<br \/>\n100 to 500 Hz, \u2265 25 A<\/td>\n<\/tr>\n<tr class=\"head\">\n<td style=\"background-color: #b3a89f;\" colspan=\"5\"><strong>Resistance<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Range<\/td>\n<td colspan=\"4\">600 \u03a9\/6 k\u03a9\/60 k\u03a9<\/td>\n<\/tr>\n<tr>\n<td>Resolution<\/td>\n<td colspan=\"4\">0.1 \u03a9\/1 \u03a9\/10 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>Accuracy<\/td>\n<td colspan=\"4\">1% \u00b1 5 digits<\/td>\n<\/tr>\n<tr class=\"head\">\n<td style=\"background-color: #b3a89f;\" colspan=\"5\"><strong>Mechanical Specifications<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Size (L x W x H)<\/td>\n<td colspan=\"4\">277 x 88 x 43 mm (55 mm for remote unit)<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td colspan=\"4\">350 g<\/td>\n<\/tr>\n<tr>\n<td>Jaw Opening<\/td>\n<td colspan=\"4\">34 mm<\/td>\n<\/tr>\n<tr>\n<td>Flexible Current Probe Diameter<\/td>\n<td colspan=\"4\">7.5 mm<\/td>\n<\/tr>\n<tr>\n<td>Flexible Current Probe Cable Length<br \/>\n(head to electronics connector)<\/td>\n<td colspan=\"4\">1.8 m<\/td>\n<\/tr>\n<tr class=\"head\">\n<td style=\"background-color: #b3a89f;\" colspan=\"5\"><strong>Environmental Specifications<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Operating Temperature<\/td>\n<td colspan=\"4\">-10\u00b0C to +50\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Storage Temperature<\/td>\n<td colspan=\"4\">-40\u00b0C to +60\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Operating Humidity<\/td>\n<td colspan=\"4\">Non condensing (&lt; 10\u00b0C)<br \/>\n\u2264 90% RH (at 10\u00b0C to 30\u00b0C)<br \/>\n\u2264 75% RH (at 30\u00b0C to 40\u00b0C)<br \/>\n\u2264 45% RH (at 40\u00b0C to 50\u00b0C)<br \/>\n(Without Condensation)<\/td>\n<\/tr>\n<tr>\n<td>Operating Altitude<\/td>\n<td colspan=\"4\">2,000 meters<\/td>\n<\/tr>\n<tr>\n<td>Storage Altitude<\/td>\n<td colspan=\"4\">12,000 meters<\/td>\n<\/tr>\n<tr>\n<td>EMI, RFI, EMC, RF<\/td>\n<td colspan=\"4\">EN 61326-1:2006, EN 61326-2-2:2006<br \/>\nETSI EN 300 328 V1.7.1:2006<br \/>\nETSI EN 300 489 V1.8.1:2008<br \/>\nFCC Part 15 Subpart C Sections 15.207, 15.209, 15.249<br \/>\nFCCID: T68-F381<br \/>\nRSS-210 IC: 6627A-F381<\/td>\n<\/tr>\n<tr>\n<td>Temperature Coefficients<\/td>\n<td colspan=\"4\">Add 0.1 x specified accuracy for each degree C above 28\u00b0C or below 18\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Wireless Frequency<\/td>\n<td colspan=\"4\">2.4 GHz ISM Band 10 meter range<\/td>\n<\/tr>\n<tr>\n<td>Safety Compliance<\/td>\n<td colspan=\"4\">ANSI\/ISA S82.02.01:2004<br \/>\nCAN\/CSA-C22.2 No. 61010-1-04<br \/>\nIEC\/EN 61010-1:2001 to 1000V CAT III, 600V CAT IV.<\/td>\n<\/tr>\n<tr>\n<td>Double Insulation Clearance<\/td>\n<td colspan=\"4\">Per IEC 61010-2-032<\/td>\n<\/tr>\n<tr>\n<td>Double Insulation Creepage<\/td>\n<td colspan=\"4\">Per IEC 61010-1<\/td>\n<\/tr>\n<tr>\n<td>Agency Approvals<\/td>\n<td class=\"certifications\" colspan=\"4\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<h2>381<\/h2>\n<p>Now one technician can do jobs that would otherwise require two people. Clamp the Fluke 381 around a conductor, remove the display and walk across the room to operate controls or remove protective equipment, all while watching real-time readings.<\/p>\n","protected":false},"featured_media":7037,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[57,1160],"product_tag":[535],"class_list":{"0":"post-7038","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-electrical","7":"product_cat-clamp-on-meters","8":"product_tag-ammeter-clamp-ac-clamp-on","10":"first","11":"instock","12":"shipping-taxable","13":"product-type-simple"},"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Pince multim\u00e8tre \u00e0 affichage distant TRMS CA\/DC avec iFlex\u00ae - Chevrier Instruments inc.<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/chevrierinstruments.com\/en\/produit\/pince-multimetre-a-affichage-distant-trms-ca-dc-avec-iflex-381\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Pince multim\u00e8tre \u00e0 affichage distant TRMS CA\/DC avec iFlex\u00ae - Chevrier Instruments inc.\" \/>\n<meta property=\"og:description\" content=\"381 Now one technician can do jobs that would otherwise require two people. Clamp the Fluke 381 around a conductor, remove the display and walk across the room to operate controls or remove protective equipment, all while watching real-time readings.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/chevrierinstruments.com\/en\/produit\/pince-multimetre-a-affichage-distant-trms-ca-dc-avec-iflex-381\/\" \/>\n<meta property=\"og:site_name\" content=\"Chevrier Instruments inc.\" \/>\n<meta property=\"article:modified_time\" content=\"2024-07-30T19:31:23+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2022\/05\/f-381-04e-1500x1000-1.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"615\" \/>\n\t<meta property=\"og:image:height\" content=\"410\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/chevrierinstruments.com\/en\/produit\/pince-multimetre-a-affichage-distant-trms-ca-dc-avec-iflex-381\/\",\"url\":\"https:\/\/chevrierinstruments.com\/en\/produit\/pince-multimetre-a-affichage-distant-trms-ca-dc-avec-iflex-381\/\",\"name\":\"Pince multim\u00e8tre \u00e0 affichage distant TRMS CA\/DC avec iFlex\u00ae - Chevrier Instruments inc.\",\"isPartOf\":{\"@id\":\"https:\/\/chevrierinstruments.com\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/chevrierinstruments.com\/en\/produit\/pince-multimetre-a-affichage-distant-trms-ca-dc-avec-iflex-381\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/chevrierinstruments.com\/en\/produit\/pince-multimetre-a-affichage-distant-trms-ca-dc-avec-iflex-381\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2022\/05\/f-381-04e-1500x1000-1.webp\",\"datePublished\":\"2022-05-17T19:16:23+00:00\",\"dateModified\":\"2024-07-30T19:31:23+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/chevrierinstruments.com\/en\/produit\/pince-multimetre-a-affichage-distant-trms-ca-dc-avec-iflex-381\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/chevrierinstruments.com\/en\/produit\/pince-multimetre-a-affichage-distant-trms-ca-dc-avec-iflex-381\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/chevrierinstruments.com\/en\/produit\/pince-multimetre-a-affichage-distant-trms-ca-dc-avec-iflex-381\/#primaryimage\",\"url\":\"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2022\/05\/f-381-04e-1500x1000-1.webp\",\"contentUrl\":\"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2022\/05\/f-381-04e-1500x1000-1.webp\",\"width\":615,\"height\":410},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/chevrierinstruments.com\/en\/produit\/pince-multimetre-a-affichage-distant-trms-ca-dc-avec-iflex-381\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\/\/chevrierinstruments.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Pince multim\u00e8tre \u00e0 affichage distant TRMS CA\/DC avec iFlex\u00ae\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/chevrierinstruments.com\/en\/#website\",\"url\":\"https:\/\/chevrierinstruments.com\/en\/\",\"name\":\"Chevrier Instruments inc.\",\"description\":\"La r\u00e9f\u00e9rence en instruments de mesure\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/chevrierinstruments.com\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Pince multim\u00e8tre \u00e0 affichage distant TRMS CA\/DC avec iFlex\u00ae - Chevrier Instruments inc.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/chevrierinstruments.com\/en\/produit\/pince-multimetre-a-affichage-distant-trms-ca-dc-avec-iflex-381\/","og_locale":"en_US","og_type":"article","og_title":"Pince multim\u00e8tre \u00e0 affichage distant TRMS CA\/DC avec iFlex\u00ae - Chevrier Instruments inc.","og_description":"381 Now one technician can do jobs that would otherwise require two people. Clamp the Fluke 381 around a conductor, remove the display and walk across the room to operate controls or remove protective equipment, all while watching real-time readings.","og_url":"https:\/\/chevrierinstruments.com\/en\/produit\/pince-multimetre-a-affichage-distant-trms-ca-dc-avec-iflex-381\/","og_site_name":"Chevrier Instruments inc.","article_modified_time":"2024-07-30T19:31:23+00:00","og_image":[{"width":615,"height":410,"url":"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2022\/05\/f-381-04e-1500x1000-1.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/chevrierinstruments.com\/en\/produit\/pince-multimetre-a-affichage-distant-trms-ca-dc-avec-iflex-381\/","url":"https:\/\/chevrierinstruments.com\/en\/produit\/pince-multimetre-a-affichage-distant-trms-ca-dc-avec-iflex-381\/","name":"Pince multim\u00e8tre \u00e0 affichage distant TRMS CA\/DC avec iFlex\u00ae - Chevrier Instruments inc.","isPartOf":{"@id":"https:\/\/chevrierinstruments.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/chevrierinstruments.com\/en\/produit\/pince-multimetre-a-affichage-distant-trms-ca-dc-avec-iflex-381\/#primaryimage"},"image":{"@id":"https:\/\/chevrierinstruments.com\/en\/produit\/pince-multimetre-a-affichage-distant-trms-ca-dc-avec-iflex-381\/#primaryimage"},"thumbnailUrl":"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2022\/05\/f-381-04e-1500x1000-1.webp","datePublished":"2022-05-17T19:16:23+00:00","dateModified":"2024-07-30T19:31:23+00:00","breadcrumb":{"@id":"https:\/\/chevrierinstruments.com\/en\/produit\/pince-multimetre-a-affichage-distant-trms-ca-dc-avec-iflex-381\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/chevrierinstruments.com\/en\/produit\/pince-multimetre-a-affichage-distant-trms-ca-dc-avec-iflex-381\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/chevrierinstruments.com\/en\/produit\/pince-multimetre-a-affichage-distant-trms-ca-dc-avec-iflex-381\/#primaryimage","url":"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2022\/05\/f-381-04e-1500x1000-1.webp","contentUrl":"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2022\/05\/f-381-04e-1500x1000-1.webp","width":615,"height":410},{"@type":"BreadcrumbList","@id":"https:\/\/chevrierinstruments.com\/en\/produit\/pince-multimetre-a-affichage-distant-trms-ca-dc-avec-iflex-381\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/chevrierinstruments.com\/en\/"},{"@type":"ListItem","position":2,"name":"Pince multim\u00e8tre \u00e0 affichage distant TRMS CA\/DC avec iFlex\u00ae"}]},{"@type":"WebSite","@id":"https:\/\/chevrierinstruments.com\/en\/#website","url":"https:\/\/chevrierinstruments.com\/en\/","name":"Chevrier Instruments inc.","description":"La r\u00e9f\u00e9rence en instruments de mesure","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/chevrierinstruments.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/product\/7038","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/media\/7037"}],"wp:attachment":[{"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/media?parent=7038"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/product_brand?post=7038"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/product_cat?post=7038"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/product_tag?post=7038"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}