{"id":8460,"date":"2022-05-17T19:22:27","date_gmt":"2022-05-17T19:22:27","guid":{"rendered":"https:\/\/chevrierinstruments.com\/produit\/hygroclip-2-standard-humidity-probe\/"},"modified":"2024-06-13T15:11:22","modified_gmt":"2024-06-13T15:11:22","slug":"hygroclip-2-standard-humidity-probe","status":"publish","type":"product","link":"https:\/\/chevrierinstruments.com\/en\/produit\/hygroclip-2-standard-humidity-probe\/","title":{"rendered":"Hygroclip 2 Standard Humidity probe"},"content":{"rendered":"<h3>Description<\/h3>\n<p>The standard Rotronic Humidity and Temperature probes can be used in application with temperatures from -50\u2026100 \u00b0C \/ 0\u2026100 %RH. With an outstanding accuracy of \u00b1 0.8 %RH \/ \u00b1 0.1\u00b0C. For calibration purposes the probes can be replaced without almost any downtime. Together with a Rotronic HF5, PF4\/5 transmitter or HP32 the HC2A-S(H) probe is the first selection for many applications.<\/p>\n<p>The HC2A-S(H) are the most sold versatile probe from Rotronic and form the basis of the product portfolio. They measure Humidity and Temperature and can calculate the dew-\/ frost point.<\/p>\n<h3>Key features<\/h3>\n<ul>\n<li>Operating range -50...100 \u00b0C \/ 0...100 %RH<\/li>\n<li>Accuracy: \u00b10.8 %RH, \u00b10.1 K, at 23 \u00b0C \u00b15 K<\/li>\n<li>Digital interface (UART) and scalable analogue outputs, 0...1 V<\/li>\n<li>GAMP compatible (HygroSoft software)<\/li>\n<\/ul>\n<table style=\"border-style: solid; width: 825px; border-color: #000000;\" border=\"1\" width=\"825\">\n<tbody>\n<tr>\n<td width=\"20%\"><\/td>\n<td width=\"20%\">HC2A-S<\/td>\n<td width=\"20%\">HC2A-SH<\/td>\n<\/tr>\n<tr>\n<td>Type<\/td>\n<td>Standard Probe<\/td>\n<td>High Precision Probe<\/td>\n<\/tr>\n<tr>\n<td>Application Range<\/td>\n<td colspan=\"2\">-50...100 \u00b0C \/ 0...100 %RH<\/td>\n<\/tr>\n<tr>\n<td>Accuracy at 23 \u00b0C<\/td>\n<td>\u00b10.8 %RH \/ \u00b10.1 K<\/td>\n<td>\u00b10.5 %RH \/ \u00b10.1 K<\/td>\n<\/tr>\n<tr>\n<td>Long-term-Stability<\/td>\n<td colspan=\"2\">Drift &lt;1%RH per year with clean air or similar. (see pollutant table in catalog etc.)<\/td>\n<\/tr>\n<tr>\n<td>Sensors<\/td>\n<td colspan=\"2\">Humidity: Rotronic HT-1 \/ Temperature PT100 1\/3 DIN Class B<\/td>\n<\/tr>\n<tr>\n<td>Filter and Filter Carrier<\/td>\n<td colspan=\"2\">Polyethylen, 40 \u00b5m (SPA-PCB-PE)<\/td>\n<\/tr>\n<tr>\n<td>Probe Housing<\/td>\n<td colspan=\"2\">Polycarbonate (black)<\/td>\n<\/tr>\n<tr>\n<td>Dimension Measurement Head<\/td>\n<td colspan=\"2\">\u00d8 15 x 108 mm<\/td>\n<\/tr>\n<tr>\n<td>Output Signals<\/td>\n<td colspan=\"2\">Digital UART \/ 2x 0\u20261 VDC<\/td>\n<\/tr>\n<tr>\n<td>Compatible<\/td>\n<td colspan=\"2\">HF5, PF4\/5, HP32<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<h2>HC2A-S,SH<\/h2>\n<p>Ultra-stable, accurate and versatile probe for temperatures -50\u2026100 \u00b0C<\/p>\n","protected":false},"featured_media":8235,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[45,361,47,56],"product_tag":[560],"class_list":{"0":"post-8460","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-measuring-devices","7":"product_cat-heating-refrigeration-air-conditioning","8":"product_cat-air-conditioning","9":"product_cat-temperature-en","10":"product_tag-sonde-pour-hygrometres-en","12":"first","13":"instock","14":"shipping-taxable","15":"product-type-variable"},"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Hygroclip 2 Standard Humidity probe - Chevrier Instruments inc.<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/chevrierinstruments.com\/en\/produit\/hygroclip-2-standard-humidity-probe\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Hygroclip 2 Standard Humidity probe - Chevrier Instruments inc.\" \/>\n<meta property=\"og:description\" content=\"HC2A-S,SH Ultra-stable, accurate and versatile probe for temperatures -50\u2026100 \u00b0C\" \/>\n<meta property=\"og:url\" content=\"https:\/\/chevrierinstruments.com\/en\/produit\/hygroclip-2-standard-humidity-probe\/\" \/>\n<meta property=\"og:site_name\" content=\"Chevrier Instruments inc.\" \/>\n<meta property=\"article:modified_time\" content=\"2024-06-13T15:11:22+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2022\/05\/1_HC2A-S_700x700px.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"700\" \/>\n\t<meta property=\"og:image:height\" content=\"700\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/chevrierinstruments.com\/en\/produit\/hygroclip-2-standard-humidity-probe\/\",\"url\":\"https:\/\/chevrierinstruments.com\/en\/produit\/hygroclip-2-standard-humidity-probe\/\",\"name\":\"Hygroclip 2 Standard Humidity probe - Chevrier Instruments inc.\",\"isPartOf\":{\"@id\":\"https:\/\/chevrierinstruments.com\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/chevrierinstruments.com\/en\/produit\/hygroclip-2-standard-humidity-probe\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/chevrierinstruments.com\/en\/produit\/hygroclip-2-standard-humidity-probe\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2022\/05\/1_HC2A-S_700x700px.jpg\",\"datePublished\":\"2022-05-17T19:22:27+00:00\",\"dateModified\":\"2024-06-13T15:11:22+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/chevrierinstruments.com\/en\/produit\/hygroclip-2-standard-humidity-probe\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/chevrierinstruments.com\/en\/produit\/hygroclip-2-standard-humidity-probe\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/chevrierinstruments.com\/en\/produit\/hygroclip-2-standard-humidity-probe\/#primaryimage\",\"url\":\"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2022\/05\/1_HC2A-S_700x700px.jpg\",\"contentUrl\":\"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2022\/05\/1_HC2A-S_700x700px.jpg\",\"width\":700,\"height\":700},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/chevrierinstruments.com\/en\/produit\/hygroclip-2-standard-humidity-probe\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\/\/chevrierinstruments.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Hygroclip 2 Standard Humidity probe\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/chevrierinstruments.com\/en\/#website\",\"url\":\"https:\/\/chevrierinstruments.com\/en\/\",\"name\":\"Chevrier Instruments inc.\",\"description\":\"La r\u00e9f\u00e9rence en instruments de mesure\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/chevrierinstruments.com\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Hygroclip 2 Standard Humidity probe - Chevrier Instruments inc.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/chevrierinstruments.com\/en\/produit\/hygroclip-2-standard-humidity-probe\/","og_locale":"en_US","og_type":"article","og_title":"Hygroclip 2 Standard Humidity probe - Chevrier Instruments inc.","og_description":"HC2A-S,SH Ultra-stable, accurate and versatile probe for temperatures -50\u2026100 \u00b0C","og_url":"https:\/\/chevrierinstruments.com\/en\/produit\/hygroclip-2-standard-humidity-probe\/","og_site_name":"Chevrier Instruments inc.","article_modified_time":"2024-06-13T15:11:22+00:00","og_image":[{"width":700,"height":700,"url":"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2022\/05\/1_HC2A-S_700x700px.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/chevrierinstruments.com\/en\/produit\/hygroclip-2-standard-humidity-probe\/","url":"https:\/\/chevrierinstruments.com\/en\/produit\/hygroclip-2-standard-humidity-probe\/","name":"Hygroclip 2 Standard Humidity probe - Chevrier Instruments inc.","isPartOf":{"@id":"https:\/\/chevrierinstruments.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/chevrierinstruments.com\/en\/produit\/hygroclip-2-standard-humidity-probe\/#primaryimage"},"image":{"@id":"https:\/\/chevrierinstruments.com\/en\/produit\/hygroclip-2-standard-humidity-probe\/#primaryimage"},"thumbnailUrl":"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2022\/05\/1_HC2A-S_700x700px.jpg","datePublished":"2022-05-17T19:22:27+00:00","dateModified":"2024-06-13T15:11:22+00:00","breadcrumb":{"@id":"https:\/\/chevrierinstruments.com\/en\/produit\/hygroclip-2-standard-humidity-probe\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/chevrierinstruments.com\/en\/produit\/hygroclip-2-standard-humidity-probe\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/chevrierinstruments.com\/en\/produit\/hygroclip-2-standard-humidity-probe\/#primaryimage","url":"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2022\/05\/1_HC2A-S_700x700px.jpg","contentUrl":"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2022\/05\/1_HC2A-S_700x700px.jpg","width":700,"height":700},{"@type":"BreadcrumbList","@id":"https:\/\/chevrierinstruments.com\/en\/produit\/hygroclip-2-standard-humidity-probe\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/chevrierinstruments.com\/en\/"},{"@type":"ListItem","position":2,"name":"Hygroclip 2 Standard Humidity probe"}]},{"@type":"WebSite","@id":"https:\/\/chevrierinstruments.com\/en\/#website","url":"https:\/\/chevrierinstruments.com\/en\/","name":"Chevrier Instruments inc.","description":"La r\u00e9f\u00e9rence en instruments de mesure","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/chevrierinstruments.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/product\/8460","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/media\/8235"}],"wp:attachment":[{"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/media?parent=8460"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/product_brand?post=8460"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/product_cat?post=8460"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/product_tag?post=8460"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}