{"id":8520,"date":"2022-05-17T19:15:58","date_gmt":"2022-05-17T19:15:58","guid":{"rendered":"https:\/\/chevrierinstruments.com\/produit\/three-phase-electrical-energy-loggers\/"},"modified":"2025-11-21T16:09:10","modified_gmt":"2025-11-21T16:09:10","slug":"three-phase-electrical-energy-loggers","status":"publish","type":"product","link":"https:\/\/chevrierinstruments.com\/en\/produit\/three-phase-electrical-energy-loggers\/","title":{"rendered":"Three-Phase Electrical Energy Loggers"},"content":{"rendered":"<h2>Key features<\/h2>\n<ul>\n<li><strong>Key measurements<\/strong>: Automatically capture and log voltage, current, power, power factor, energy and associated values<\/li>\n<li><strong>Convenient instrument powering<\/strong>: You can power the instrument directly from the measured circuit instead of mains outlets<\/li>\n<li><strong>Highest safety rating in the industry<\/strong>: 600 V CAT IV\/1000 V CAT III rated for use at the service entrance and downstream<\/li>\n<\/ul>\n<p class=\"link-btn-style btn-blue\"><a href=\"https:\/\/www.fluke.com\/en-ca\/support\/software-downloads\/fluke-1732-1734-1736-1738-power-loggers?utm_source=chatgpt.com#country-picker-mobile\">Download the software<\/a><\/p>\n<h4>Specifications<\/h4>\n<table style=\"border-color: #000000; border-style: solid;\" border=\"1\">\n<tbody>\n<tr>\n<td colspan=\"6\">Accuracy<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Parameter<\/td>\n<td><b>Range<\/b><\/td>\n<td><b>Resolution<\/b><\/td>\n<td colspan=\"2\"><b>Intrinsic Accuracy at Reference Conditions (% of Reading +% of Full Scale)<\/b><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Voltage<\/td>\n<td>1000 V<\/td>\n<td>0.1 V<\/td>\n<td colspan=\"2\">\u00b1(0.2% + 0.01%)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"8\">Current: Direct input<\/td>\n<td rowspan=\"2\"><b>i17xx-flex 1500 12\"<\/b><\/td>\n<td>150 A<\/td>\n<td>0.1 A<\/td>\n<td colspan=\"2\">\u00b1(1% + 0.02%)<\/td>\n<\/tr>\n<tr>\n<td>1500 A<\/td>\n<td>1 A<\/td>\n<td colspan=\"2\">\u00b1(1% + 0.02%)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\"><b>i17xx-flex 3000 24\"<\/b><\/td>\n<td>300 A<\/td>\n<td>1 A<\/td>\n<td colspan=\"2\">\u00b1(1% + 0.03%)<\/td>\n<\/tr>\n<tr>\n<td>3000 A<\/td>\n<td>10 A<\/td>\n<td colspan=\"2\">\u00b1(1% + 0.03%)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\"><b>i17xx-flex 6000 36\"<\/b><\/td>\n<td>600 A<\/td>\n<td>1 A<\/td>\n<td colspan=\"2\">\u00b1(1.5% + 0.03%)<\/td>\n<\/tr>\n<tr>\n<td>6000 A<\/td>\n<td>10 A<\/td>\n<td colspan=\"2\">\u00b1(1.5% + 0.03%)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\"><b>i40s-EL clamp<\/b><\/td>\n<td>4 A<\/td>\n<td>1 mA<\/td>\n<td colspan=\"2\">\u00b1(0.7% + 0.02%)<\/td>\n<\/tr>\n<tr>\n<td>40 A<\/td>\n<td>10 mA<\/td>\n<td colspan=\"2\">\u00b1(0.7% + 0.02%)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Frequency<\/td>\n<td>42.5 Hz to 69 Hz<\/td>\n<td>0.01 Hz<\/td>\n<td colspan=\"2\">\u00b1(0.1%)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Auxillary input<\/td>\n<td>\u00b110 V dc<\/td>\n<td>0.1 mV<\/td>\n<td colspan=\"2\">\u00b1(0.2% + 0.02%)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Voltage min\/max<\/td>\n<td>1000 V<\/td>\n<td>0.1 V<\/td>\n<td colspan=\"2\">\u00b1(1% + 0.1%)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Current min\/max<\/td>\n<td>Defined by accessory<\/td>\n<td>Defined by accessory<\/td>\n<td colspan=\"2\">\u00b1(5% + 0.2%)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">THD on voltage<\/td>\n<td>1000%<\/td>\n<td>0.1%<\/td>\n<td colspan=\"2\">\u00b10.5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">THD on current<\/td>\n<td>1000%<\/td>\n<td>0.1%<\/td>\n<td colspan=\"2\">\u00b10.5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\">Intrinsic Uncertainty \u00b1(% of reading +% of range)\u00b9<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Parameter<\/td>\n<td rowspan=\"2\"><b>Influence quantity<\/b><\/td>\n<td><b>iFlex1500-12<\/b><\/td>\n<td><b>iFlex3000-24<\/b><\/td>\n<td><b>iFlex6000-36<\/b><\/td>\n<td><b>i40S-EL<\/b><\/td>\n<\/tr>\n<tr>\n<td><b>150 A \/ 1500 A<\/b><\/td>\n<td><b>300 A \/ 3000 A<\/b><\/td>\n<td><b>600 A \/ 6000 A<\/b><\/td>\n<td><b>4 A \/ 40 A<\/b><\/td>\n<\/tr>\n<tr>\n<td>Active Power\u00a0P<\/td>\n<td>PF \u2265 0.99<\/td>\n<td>1.2% + 0.005%<\/td>\n<td>1.2% + 0.0075%<\/td>\n<td>1.7% + 0.0075%<\/td>\n<td>1.2% + 0.005%<\/td>\n<\/tr>\n<tr>\n<td>Active Energy\u00a0E<sub>a<\/sub><\/td>\n<td>PF \u2265 0.99<\/td>\n<td>1.2% + 0.005%<\/td>\n<td>1.2% + 0.0075%<\/td>\n<td>1.7% + 0.0075%<\/td>\n<td>1.2% + 0.005%<\/td>\n<\/tr>\n<tr>\n<td>Apparent power\u00a0S<\/td>\n<td>0 \u2264 PF \u2264 1<\/td>\n<td>1.2% + 0.005%<\/td>\n<td>1.2% + 0.0075%<\/td>\n<td>1.7% + 0.0075%<\/td>\n<td>1.2% + 0.005%<\/td>\n<\/tr>\n<tr>\n<td>Apparent Energy\u00a0E<sub>ap<\/sub><\/td>\n<td>0 \u2264 PF \u2264 1<\/td>\n<td>1.2% + 0.005%<\/td>\n<td>1.2% + 0.0075%<\/td>\n<td>1.7% + 0.0075%<\/td>\n<td>1.2% + 0.005%<\/td>\n<\/tr>\n<tr>\n<td>Reactive power\u00a0Q<\/td>\n<td>0 \u2264 PF \u2264 1<\/td>\n<td colspan=\"4\">2.5% of measured apparent power<\/td>\n<\/tr>\n<tr>\n<td>Reactive Energy\u00a0E<sub>r<\/sub><\/td>\n<td>0 \u2264 PF \u2264 1<\/td>\n<td colspan=\"4\">2.5% of measured apparent power<\/td>\n<\/tr>\n<tr>\n<td>Power Factor PF<\/td>\n<td>-<\/td>\n<td colspan=\"4\">\u00b10.025<\/td>\n<\/tr>\n<tr>\n<td>Displacement Power Factor<\/td>\n<td>-<\/td>\n<td colspan=\"4\">\u00b10.025<\/td>\n<\/tr>\n<tr>\n<td>DBF\/cos\u03d5<\/td>\n<td>-<\/td>\n<td colspan=\"4\">\u00b10.025<\/td>\n<\/tr>\n<tr>\n<td>Additional uncertainty in% of range\u00b9<\/td>\n<td>V<sub>P-N<\/sub>&gt;250 V<\/td>\n<td>0.015%<\/td>\n<td>0.0225%<\/td>\n<td>0.0225%<\/td>\n<td>0.015%<\/td>\n<\/tr>\n<tr>\n<td class=\"small\" colspan=\"6\">\u00b9Range = 1000 V x Irange<br \/>\nReference conditions:<\/p>\n<ul class=\"small\">\n<li><b>Environmental:<\/b>\u00a023 \u00b0C \u00b15 \u00b0C, instrument operating for at least 30 minutes, no external electrical\/magnetic field, RH &lt;65%<\/li>\n<li><b>Input conditions:<\/b>\u00a0Cos\u03d5\/PF=1, Sinusoidal signal f=50 Hz\/60 Hz, power supply 120 V\/230 V \u00b110%.<\/li>\n<li><b>Current and power specifications:<\/b>\u00a0Input voltage 1 ph: 120 V\/230 V or 3 ph wye\/delta: 230 V\/400 V Input current: I &gt; 10% of Irange<\/li>\n<li><b>Primary conductor of clamps or Rogowski coil in center position<\/b><\/li>\n<li><b>Temperature coefficient:<\/b>\u00a0Add 0.1 x specified accuracy for each degree C above 28 \u00b0C or below 18 \u00b0C<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table style=\"border-style: solid; border-color: #000000;\" border=\"1\">\n<tbody>\n<tr>\n<td colspan=\"2\">Electrical Specifications<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Power Supply<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Voltage range<\/td>\n<td>100 V to 500 V using safety plug input when powering from the measurement circuit<\/td>\n<\/tr>\n<tr>\n<td>100 V to 240 V using standard power cord (IEC 60320 C7)<\/td>\n<\/tr>\n<tr>\n<td>Power consumption<\/td>\n<td>Maximum 50 VA (max. 15 VA when powered using IEC 60320 input)<\/td>\n<\/tr>\n<tr>\n<td>Efficiency<\/td>\n<td>\u2265 68.2% (in accordance with energy efficiency regulations)<\/td>\n<\/tr>\n<tr>\n<td>Maximum no-load consumption<\/td>\n<td>&lt; 0.3 W only when powered using IEC 60320 input<\/td>\n<\/tr>\n<tr>\n<td>Mains power frequency<\/td>\n<td>50\/60 Hz \u00b115%<\/td>\n<\/tr>\n<tr>\n<td>Battery<\/td>\n<td>Li-ion 3.7 V, 9.25 Wh, customer-replaceable<\/td>\n<\/tr>\n<tr>\n<td>On-battery runtime<\/td>\n<td>Four hours in standard operating mode, up to 5.5 hours in power saving mode<\/td>\n<\/tr>\n<tr>\n<td>Charging time<\/td>\n<td>&lt; 6 hours<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Data Acquisition<\/td>\n<\/tr>\n<tr>\n<td>Resolution<\/td>\n<td>16-bit synchronous sampling<\/td>\n<\/tr>\n<tr>\n<td>Sampling frequency<\/td>\n<td>10.24 kHz at 50\/60 Hz, synchronized to mains frequency<\/td>\n<\/tr>\n<tr>\n<td>Input signal frequency<\/td>\n<td>50\/60 Hz (42.5 to 69 Hz)<\/td>\n<\/tr>\n<tr>\n<td>Circuit types<\/td>\n<td>1-\u03c6, 1-\u03c6 IT, Split phase, 3-\u03c6 delta, 3-\u03c6 wye, 3-\u03c6 wye IT, 3-\u03c6 wye balanced, 3-\u03c6 Aron\/Blondel (2-element delta), 3-\u03c6 delta open leg, Currents only (load studies)<\/td>\n<\/tr>\n<tr>\n<td>Data storage<\/td>\n<td>Internal flash memory (not user replaceable)<\/td>\n<\/tr>\n<tr>\n<td>Memory size<\/td>\n<td>Typical 10 logging sessions of 8 weeks with 1-minute intervals and 500 events\u00b9<\/td>\n<\/tr>\n<tr>\n<td class=\"small\" colspan=\"2\">\u00b9The number of possible logging sessions and logging period depends on user requirements.<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Basic Interval<\/td>\n<\/tr>\n<tr>\n<td>Measured parameters<\/td>\n<td>Voltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental power, DPF, energy<\/td>\n<\/tr>\n<tr>\n<td>Averaging interval<\/td>\n<td>User selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min<\/td>\n<\/tr>\n<tr>\n<td>Averaging time min\/max values<\/td>\n<td>Voltage, Current: Full cycle RMS updated every half cycle Aux, Power: 200ms<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Demand Interval (Energy Meter Mode)<\/td>\n<\/tr>\n<tr>\n<td>Measured parameters<\/td>\n<td>Energy (Wh, varh, VAh), PF, maximum demand, cost of energy<\/td>\n<\/tr>\n<tr>\n<td>Interval<\/td>\n<td>User selectable: 5 min, 10 min, 15 min, 20 min, 30 min, off<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Standards Compliance<\/td>\n<\/tr>\n<tr>\n<td>Power<\/td>\n<td>IEEE 1459<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Interfaces<\/td>\n<\/tr>\n<tr>\n<td>USB-A<\/td>\n<td>File transfer via USB flash drive, firmware updates<br \/>\nMax. current: 120 mA<\/td>\n<\/tr>\n<tr>\n<td>WiFi<\/td>\n<td>File transfer and remote control via direct connection or WiFi infrastructure<\/td>\n<\/tr>\n<tr>\n<td>Bluetooth<\/td>\n<td>Read auxiliary measurement data from Fluke Connect\u00ae 3000 series modules (requires 1734, or 1732 upgrade option)<\/td>\n<\/tr>\n<tr>\n<td>USB-mini<\/td>\n<td>Data download device to PC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Voltage Inputs<\/td>\n<\/tr>\n<tr>\n<td>Number of inputs<\/td>\n<td>4 (3 phases and neutral)<\/td>\n<\/tr>\n<tr>\n<td>Maximum input voltage<\/td>\n<td>1000 Vrms, CF 1.7<\/td>\n<\/tr>\n<tr>\n<td>Input impedance<\/td>\n<td>10 M\u03a9<\/td>\n<\/tr>\n<tr>\n<td>Bandwidth (-3 dB)<\/td>\n<td>42.5 Hz - 3.5 kHz<\/td>\n<\/tr>\n<tr>\n<td>Scaling<\/td>\n<td>1:1 and variable<\/td>\n<\/tr>\n<tr>\n<td>Measurement category<\/td>\n<td>1000 V CAT III\/600 V CAT IV<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Current Inputs<\/td>\n<\/tr>\n<tr>\n<td>Number of inputs<\/td>\n<td>3, mode selected automatically for attached sensor<\/td>\n<\/tr>\n<tr>\n<td>Input voltage<\/td>\n<td>Clamp input: 500 mVrms\/50 mVrms; CF 2.8<\/td>\n<\/tr>\n<tr>\n<td>Rogowski coil input<\/td>\n<td>150 mVrms\/15 mVrms at 50 Hz, 180 mVrms\/18 mVrms at 60 Hz; CF 4; all at nominal probe range<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">Range<\/td>\n<td>1 A to 150 A\/10 A to 1500 A with thin flexible current probe i17XX-flex1500 12\"<\/td>\n<\/tr>\n<tr>\n<td>3 A to 300 A\/30 A to 3000 A with thin flexible current probe i17XX-flex3000 24\"<\/td>\n<\/tr>\n<tr>\n<td>6 A to 600 A\/60 A to 6000 A with thin flexible current probe i17XX-flex6000 36\"<\/td>\n<\/tr>\n<tr>\n<td>40 mA to 4 A\/0.4 A to 40 A with 40 A clamp i40s-EL<\/td>\n<\/tr>\n<tr>\n<td>Bandwidth (-3 dB)<\/td>\n<td>42.5 Hz - 3.5 kHz<\/td>\n<\/tr>\n<tr>\n<td>Scaling<\/td>\n<td>1:1 and variable<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Auxiliary Inputs<\/td>\n<\/tr>\n<tr>\n<td>Number of inputs<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>Input range<\/td>\n<td>0 to \u00b110 V dc, 1reading\/s<\/td>\n<\/tr>\n<tr>\n<td>Scale factor (available 2014)<\/td>\n<td>Format: mx + b (gain and offset) user configurable<\/td>\n<\/tr>\n<tr>\n<td>Displayed units (available 2014)<\/td>\n<td>User configurable (7 characters, for example, \u00b0C, psi, or m\/s)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Wireless Connection<\/td>\n<\/tr>\n<tr>\n<td>Number of inputs<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>Supported modules<\/td>\n<td>Fluke Connect\u00ae 3000 series<\/td>\n<\/tr>\n<tr>\n<td>Acquisition<\/td>\n<td>1 reading\/s<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Environmental Specifications<\/td>\n<\/tr>\n<tr>\n<td>Operating temperature<\/td>\n<td>-10 \u00b0C to +50 \u00b0C (14 \u00b0F to 122 \u00b0F)<\/td>\n<\/tr>\n<tr>\n<td>Storage temperature<\/td>\n<td>-20 \u00b0C to +60 \u00b0C (-4 \u00b0F to 140 \u00b0F), with battery: -20 \u00b0C to +50 \u00b0C (-4 \u00b0F to 122 \u00b0F)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">Operating humidity<\/td>\n<td>10 \u00b0C to 30 \u00b0C (50 \u00b0F to 86 \u00b0F) max. 95% RH<\/td>\n<\/tr>\n<tr>\n<td>30 \u00b0C to 40 \u00b0C (86 \u00b0F to 104 \u00b0F) max. 75% RH<\/td>\n<\/tr>\n<tr>\n<td>40 \u00b0C to 50 \u00b0C (104 \u00b0F to 122 \u00b0F) max. 45% RH<\/td>\n<\/tr>\n<tr>\n<td>Operating altitude<\/td>\n<td>2000 m (up to 4000 m derate to 1000 V CAT II\/600 V CAT III\/300 V CAT IV)<\/td>\n<\/tr>\n<tr>\n<td>Storage altitude<\/td>\n<td>12,000m<\/td>\n<\/tr>\n<tr>\n<td>Enclosure<\/td>\n<td>IP50 in accordance with EN60529<\/td>\n<\/tr>\n<tr>\n<td>Vibration<\/td>\n<td>MIL-T-28800E, Type 3, Class III, Style B<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">Safety<\/td>\n<td>IEC 61010-1<\/td>\n<\/tr>\n<tr>\n<td>IEC Mains Input: Overvoltage Category II, Pollution Degree 2<\/td>\n<\/tr>\n<tr>\n<td>Voltage Terminals: Overvoltage Category IV, Pollution Degree 2<\/td>\n<\/tr>\n<tr>\n<td>IEC 61010-2-031: CAT IV 600 V \/ CAT III 1000 V<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">Electromagnetic compatibility<\/td>\n<td>EN 61326-1: Industrial CISPR 11: Group 1, Class A<\/td>\n<\/tr>\n<tr>\n<td>Korea (KCC): Class A Equipment (industrial broadcasting and communication equipment)<\/td>\n<\/tr>\n<tr>\n<td>USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103<\/td>\n<\/tr>\n<tr>\n<td>Temperature coefficient<\/td>\n<td>0.1 x accuracy specification\/\u00b0C<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">General Specifications<\/td>\n<\/tr>\n<tr>\n<td>Color LCD display<\/td>\n<td>4.3-inch active matrix TFT, 480 pixels x 272 pixels, resistive touch panel<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">Warranty<\/td>\n<td>Instrument and power supply: Two-years (battery not included)<\/td>\n<\/tr>\n<tr>\n<td>Accessories: one-year<\/td>\n<\/tr>\n<tr>\n<td>Calibration cycle: two-years<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">Dimensions<\/td>\n<td>Instrument: 19.8 x 16.7 x 5.5 cm (7.8 x 6.6 x 2.2 in)<\/td>\n<\/tr>\n<tr>\n<td>Power supply: 13.0 x 13.0 x 4.5 cm (5.1 x 5.1 x 1.8 in)<\/td>\n<\/tr>\n<tr>\n<td>Instrument with power supply attached: 19.8 x 16.7 x 9 cm (7.8 x 6.6 x 3.5 in)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Weight<\/td>\n<td>Instrument: 1.1 kg (2.5 lb)<\/td>\n<\/tr>\n<tr>\n<td>Power supply: 400 g (0.9 lb)<\/td>\n<\/tr>\n<tr>\n<td>Tamper protection<\/td>\n<td>Kensington lock slot<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">i17xx-flex 1500 12\" Flexible Current Probe Specifications<\/td>\n<\/tr>\n<tr>\n<td>Measuring range<\/td>\n<td>1 to 150 A ac\/10 to 1500 A ac<\/td>\n<\/tr>\n<tr>\n<td>Nondestructive current<\/td>\n<td>100 kA (50\/60 Hz)<\/td>\n<\/tr>\n<tr>\n<td>Intrinsic error at reference condition*<\/td>\n<td>\u00b10.7% of reading<\/td>\n<\/tr>\n<tr>\n<td>Accuracy 173x + iFlex<\/td>\n<td>\u00b1(1% of reading + 0.02% of range)<\/td>\n<\/tr>\n<tr>\n<td>Temperature coefficient over operating temperature range<\/td>\n<td>0.05% of reading\/\u00b0C 0.09% of reading\/\u00b0F<\/td>\n<\/tr>\n<tr>\n<td>Working voltage<\/td>\n<td>1000 V CAT III, 600 V CAT IV<\/td>\n<\/tr>\n<tr>\n<td>Probe cable length<\/td>\n<td>305 mm (12 in)<\/td>\n<\/tr>\n<tr>\n<td>Probe cable diameter<\/td>\n<td>7.5 mm (0.3 in)<\/td>\n<\/tr>\n<tr>\n<td>Minimum bending radius<\/td>\n<td>38 mm (1.5 in)<\/td>\n<\/tr>\n<tr>\n<td>Output cable length<\/td>\n<td>2 m (6.6 ft)<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>115 g<\/td>\n<\/tr>\n<tr>\n<td>Probe cable material<\/td>\n<td>TPR<\/td>\n<\/tr>\n<tr>\n<td>Coupling material<\/td>\n<td>POM + ABS\/PC<\/td>\n<\/tr>\n<tr>\n<td>Output cable<\/td>\n<td>TPR\/PVC<\/td>\n<\/tr>\n<tr>\n<td>Operating temperature<\/td>\n<td>-20 \u00b0C to +70 \u00b0C (-4 \u00b0F to 158 \u00b0F) temperature of conductor under test shall not exceed 80 \u00b0C (176 \u00b0F)<\/td>\n<\/tr>\n<tr>\n<td>Temperature, non-operating<\/td>\n<td>-40 \u00b0C to +80 \u00b0C (-40 \u00b0F to 176 \u00b0F)<\/td>\n<\/tr>\n<tr>\n<td>Relative humidity, operating<\/td>\n<td>15% to 85% non-condensing<\/td>\n<\/tr>\n<tr>\n<td>IP rating<\/td>\n<td>IEC 60529:IP50<\/td>\n<\/tr>\n<tr>\n<td>Warranty<\/td>\n<td>One-year<\/td>\n<\/tr>\n<tr>\n<td class=\"small\" colspan=\"2\">* Reference condition:<\/p>\n<ul>\n<li>Environmental: 23 \u00b0C \u00b15 \u00b0C, no external electrical\/magnetic field, RH 65%<\/li>\n<li>Primary conductor in center position<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<h2>1732 and 1734<\/h2>\n<p>Profiling energy usage across your facility helps you identify opportunities for energy savings, and provides you with the data you need to act on them. The new\u00a0<a href=\"https:\/\/www.fluke.com\/en-ca\/support\/software-downloads\/fluke-energy-analyze-plus\" target=\"_blank\" rel=\"noopener\">Energy Analyze<\/a>\u00a0software package allows you to compare multiple data points over time to build a complete picture of energy usage, which is the first step to reduce the cost of your energy bill.<\/p>\n","protected":false},"featured_media":8516,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[1604,550,57,1161],"product_tag":[1275,1274],"class_list":{"0":"post-8520","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-current-voltage","7":"product_cat-data-loggers","8":"product_cat-electrical","9":"product_cat-energy-quality-meters","10":"product_tag-energy-meter","11":"product_tag-three-phase-electrical-energy-loggers","13":"first","14":"instock","15":"shipping-taxable","16":"product-type-variable"},"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Three-Phase Electrical Energy Loggers - Chevrier Instruments inc.<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/chevrierinstruments.com\/en\/produit\/three-phase-electrical-energy-loggers\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Three-Phase Electrical Energy Loggers - Chevrier Instruments inc.\" \/>\n<meta property=\"og:description\" content=\"1732 and 1734 Profiling energy usage across your facility helps you identify opportunities for energy savings, and provides you with the data you need to act on them. The new\u00a0Energy Analyze\u00a0software package allows you to compare multiple data points over time to build a complete picture of energy usage, which is the first step to reduce the cost of your energy bill.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/chevrierinstruments.com\/en\/produit\/three-phase-electrical-energy-loggers\/\" \/>\n<meta property=\"og:site_name\" content=\"Chevrier Instruments inc.\" \/>\n<meta property=\"article:modified_time\" content=\"2025-11-21T16:09:10+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2022\/05\/fluke-1732-1734-energy-logger-500x000-1.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1230\" \/>\n\t<meta property=\"og:image:height\" content=\"820\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"8 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/chevrierinstruments.com\/en\/produit\/three-phase-electrical-energy-loggers\/\",\"url\":\"https:\/\/chevrierinstruments.com\/en\/produit\/three-phase-electrical-energy-loggers\/\",\"name\":\"Three-Phase Electrical Energy Loggers - Chevrier Instruments inc.\",\"isPartOf\":{\"@id\":\"https:\/\/chevrierinstruments.com\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/chevrierinstruments.com\/en\/produit\/three-phase-electrical-energy-loggers\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/chevrierinstruments.com\/en\/produit\/three-phase-electrical-energy-loggers\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2022\/05\/fluke-1732-1734-energy-logger-500x000-1.webp\",\"datePublished\":\"2022-05-17T19:15:58+00:00\",\"dateModified\":\"2025-11-21T16:09:10+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/chevrierinstruments.com\/en\/produit\/three-phase-electrical-energy-loggers\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/chevrierinstruments.com\/en\/produit\/three-phase-electrical-energy-loggers\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/chevrierinstruments.com\/en\/produit\/three-phase-electrical-energy-loggers\/#primaryimage\",\"url\":\"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2022\/05\/fluke-1732-1734-energy-logger-500x000-1.webp\",\"contentUrl\":\"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2022\/05\/fluke-1732-1734-energy-logger-500x000-1.webp\",\"width\":1230,\"height\":820},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/chevrierinstruments.com\/en\/produit\/three-phase-electrical-energy-loggers\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\/\/chevrierinstruments.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Three-Phase Electrical Energy Loggers\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/chevrierinstruments.com\/en\/#website\",\"url\":\"https:\/\/chevrierinstruments.com\/en\/\",\"name\":\"Chevrier Instruments inc.\",\"description\":\"La r\u00e9f\u00e9rence en instruments de mesure\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/chevrierinstruments.com\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Three-Phase Electrical Energy Loggers - Chevrier Instruments inc.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/chevrierinstruments.com\/en\/produit\/three-phase-electrical-energy-loggers\/","og_locale":"en_US","og_type":"article","og_title":"Three-Phase Electrical Energy Loggers - Chevrier Instruments inc.","og_description":"1732 and 1734 Profiling energy usage across your facility helps you identify opportunities for energy savings, and provides you with the data you need to act on them. The new\u00a0Energy Analyze\u00a0software package allows you to compare multiple data points over time to build a complete picture of energy usage, which is the first step to reduce the cost of your energy bill.","og_url":"https:\/\/chevrierinstruments.com\/en\/produit\/three-phase-electrical-energy-loggers\/","og_site_name":"Chevrier Instruments inc.","article_modified_time":"2025-11-21T16:09:10+00:00","og_image":[{"width":1230,"height":820,"url":"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2022\/05\/fluke-1732-1734-energy-logger-500x000-1.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"8 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/chevrierinstruments.com\/en\/produit\/three-phase-electrical-energy-loggers\/","url":"https:\/\/chevrierinstruments.com\/en\/produit\/three-phase-electrical-energy-loggers\/","name":"Three-Phase Electrical Energy Loggers - Chevrier Instruments inc.","isPartOf":{"@id":"https:\/\/chevrierinstruments.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/chevrierinstruments.com\/en\/produit\/three-phase-electrical-energy-loggers\/#primaryimage"},"image":{"@id":"https:\/\/chevrierinstruments.com\/en\/produit\/three-phase-electrical-energy-loggers\/#primaryimage"},"thumbnailUrl":"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2022\/05\/fluke-1732-1734-energy-logger-500x000-1.webp","datePublished":"2022-05-17T19:15:58+00:00","dateModified":"2025-11-21T16:09:10+00:00","breadcrumb":{"@id":"https:\/\/chevrierinstruments.com\/en\/produit\/three-phase-electrical-energy-loggers\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/chevrierinstruments.com\/en\/produit\/three-phase-electrical-energy-loggers\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/chevrierinstruments.com\/en\/produit\/three-phase-electrical-energy-loggers\/#primaryimage","url":"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2022\/05\/fluke-1732-1734-energy-logger-500x000-1.webp","contentUrl":"https:\/\/chevrierinstruments.com\/wp-content\/uploads\/2022\/05\/fluke-1732-1734-energy-logger-500x000-1.webp","width":1230,"height":820},{"@type":"BreadcrumbList","@id":"https:\/\/chevrierinstruments.com\/en\/produit\/three-phase-electrical-energy-loggers\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/chevrierinstruments.com\/en\/"},{"@type":"ListItem","position":2,"name":"Three-Phase Electrical Energy Loggers"}]},{"@type":"WebSite","@id":"https:\/\/chevrierinstruments.com\/en\/#website","url":"https:\/\/chevrierinstruments.com\/en\/","name":"Chevrier Instruments inc.","description":"La r\u00e9f\u00e9rence en instruments de mesure","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/chevrierinstruments.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/product\/8520","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/media\/8516"}],"wp:attachment":[{"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/media?parent=8520"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/product_brand?post=8520"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/product_cat?post=8520"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/chevrierinstruments.com\/en\/wp-json\/wp\/v2\/product_tag?post=8520"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}