Through calibration, we verify and, if necessary, adjust instruments to conform to the manufacturer’s specifications. A label is affixed to the instrument with the new calibration date and the next expiration date, and a calibration report is provided without data.
The calibration certificate includes a calibration with a report on the comparison data, and the previous measurements are written on the certificate.
All the calibration certificates we issue are referenced since our calibrations are certified and referenced to NIST or CNRC, as prescribed in our quality manual.
Our calibration laboratory operates in accordance with ISO 17025:2017. SCC Accredited Laboratory; NRC CLAS 2016-01 Certificate.
ISO 17025 CCN Accreditation Certificate
We are also able to calibrate your instruments IN THE FACTORY with the following specialties:
Air speed/air flow
Download the service form (one per service)
TEMPERATURE (-196, -80 and -30 to 600 °C)
(-200 to +2000 °C with calibrator)
Download the service form (one per service)
RELATIVE HUMIDITY (0 TO 98%) – DEW POINT
We calibrate all known brands: KIMO, ACR, DWYER, HANNA, NOVASINA, ROTRONIC, VAISALA, FISHER, COLE PARMER, and more
Download the service form (one per service)
PRESSURE
(vacuum to 16,000 psi [110,000 kPa])
Pressure differential up to 60 in. WCat 16 000 psi [110 000 kPa])
Download the service form (one per service)
ELECTRICAL MEASUREMENT INSTRUMENTS
Download the service form (one per service)
Carbon dioxide (CO2); Explosive gases (LEL); Carbon monoxide (CO); Oxygen (O2); Hydrogen sulfide (H2S)
Trace gases such as ozone (O3), volatile organic compounds (VOCs), etc.
October 2026.
By default, all portable gas detectors will now be calibrated with a 6-month validity period.
This change is intended to align with best practices in occupational health and safety, as well as the requirements typically associated with the use of gas detectors in work environments where worker safety depends on the reliability of measurements. The CNESST requires employers to implement the necessary measures to ensure the reliability of equipment used to prevent the risk of exposure to hazardous gases. Because gas detection is a critical safety component, periodic calibration is essential to ensure accurate readings and the proper functioning of alarms. [cnesst.gouv.qc.ca]
If a client explicitly requests a 12-month interval, we may apply it only if the client submits a written request and formally agrees to it.
In such cases:
Please remember to include a fully completed service form with your shipment.
Download the service form (one per service)
Calibrated instruments
Standards used
DIMENSIONS
Calibrated instruments
Calibrated instruments
Note: Where necessary, we call on specialized and ISO-recognized firms to calibrate certain instruments.
We can perform the calibration directly in the factory, or you can send the instruments to us via your carrier, as you prefer.
For more information on our calibration laboratory, please contact the laboratory’s customer service department: