Description
With this information it determines the "What it feels like" temperature. The R6250SD is OSHA recommended with a user-adjustable WBGT audible alarm and the ability to adjust settings for indoor temperature measurement. Featuring, Data hold, Max/Min functions, and an easy-to-read backlit LCD display. Using a SD card (max 16GB), a user can manually record up to 99 readings or automatically by selecting a desired sampling rate from 1 to 3600 seconds. Quickly generate an Excel file with raw data, all without the use of software. Optional accessories include a tripod and AC adapter for continuous long-term monitoring.
Features
- Measures temperature, humidity, dew point, wet bulb, black globe, indoor/outdoor WBGT
- Wet Bulb Globe Temperature (WBGT) considers the effects of temperature, humidity and direct or radiant sunlight
- In/Out function displays the WBGT value with or without direct sun exposure
- Black Globe Temperature (TG) monitors the effects of direct solar radiation on an exposed surface
- Adjustable audible alarm
- User selectable unit of measure (°F or °C)
- Data hold and Max/Min functions
- Real-time data logger with integrated SD memory card
- User selectable sampling rate from 1 to 3600 seconds
- Easy-to-read backlit LCD display
- Tripod mount for long-term monitoring
- Low battery indicator and auto shut off
REED R6250SD Specifications
Temperature | |
Measuring Ranges | Air: 32 to 122.0°F (0 to 50.0°C) Dew Point: -13.5 to 120.1°F (-25.3 to 48.9°C) Wet Bulb: -6.9 to 122.0°F (-21.6 to 50°C) Black Globe: 32 to 176°F (0 to 80°C) Indoor WBGT: 32 to 138°F (0 to 59°C) Outdoor WBGT: 32 to 132°F (0 to 56°C) |
Accuracy | Air: ±1.5°F (±0.8°C) Black Globe: ±1.1°F (±0.6°C) Indoor WBGT: ±2.7°F (±1.5°C) Outdoor WBGT: ±3.6°F (±2°C) |
Resolution | 0.1°F/°C |
Humidity | |
Measuring Ranges | 5 to 95% RH |
Accuracy | >70% RH: ±(3% rdg + 1% RH) <70% RH: ±3% RH |
Resolution | 0.1% RH |
General Specifications | |
Indoor Formula | 0.7WB + 0.3TG |
Indoor Range | 32 to 138°F (0 to 59°C) |
Indoor Accuracy | ±2.7°F (±1.5°C) |
Outdoor Formula | 0.7WB + 0.2TG + 0.1TA |
Outdoor Range | 32 to 132°F (0 to 56°C) |
Outdoor Accuracy | ±3.6°F (±2°C) |
Response Time | 1 second |
Display | 4-digit dual LCD |
Backlit Display | Yes |
Data Hold | Yes |
Min | Yes |
Max | Yes |
Datalogging Capabilities | Yes |
Real-Time Clock and Date Stamp | Yes |
Selectable Sampling Rate | Yes (1, 2, 5, 10, 30, 60, 120, 300, 600, 1800, 3600 seconds) |
External Memory | Yes, expandable up to 16GB with SD card (optional) |
Auto Shut-off | Yes (after 10 minutes/off) |
Kick Stand | Yes |
Tripod Mountable | Yes |
Low Battery Indicator | Yes |
Power Supply | 6 x AA Batteries or AC Adapter (optional) |
Data Output | Yes (RS-232) |
Product Certifications | CE |
Operating Temperature | 32 to 122°F (0 to 50°C) |
Storage Temperature | 14 to 140°F (-10 to 60°C) |
Operating Humidity Range | 10 to 85% |
Dimensions | Instrument: 7.0 x 2.7 x 1.8" (177 x 68 x 45mm) Black Brass Ball Diameter: 2.9" (75mm) |
Weight | 1.1lb (515g) |