Secondary Standard PRTs

5626/5628

Fluke Calibration’s high-temp secondary standards fill the gap between affordable, but temperature-limited secondary PRTs (platinum resistance thermometers) and more expensive, highly accurate SPRTs (standard platinum resistance thermometers).

Modele

  • Secondary Standard PRTs - 5626-12-X

    Secondary Standard PRT (0.25 in dia x 12 in), 100 Ω, –200 °C to 661 °C, (17025 accredited calibration included. Traceable to NIST standards.)

  • Secondary Standard PRTs - 5626-15-X

    Secondary Standard PRT (0.25 in dia x 15 in), 100 Ω, –200 °C to 661 °C,(17025 accredited calibration included. Traceable to NIST standards.)

  • Secondary Standard PRTs - 5626-20-X

    High-temp PRT, 100 Ω, 508 mm (20 in) Includes case, (17025 accredited calibration included. Traceable to NIST standards.)

  • Secondary Standard PRTs - 5628-12-X

    Secondary Standard PRT (0.25 in dia x 12 in), 25.5 Ω, –200 °C to 661 °C,(17025 accredited calibration included. Traceable to NIST standards.)

  • Secondary Standard PRTs - 5628-15-X

    Secondary Standard PRT (0.25 in dia x 15 in), 25.5 Ω, –200 °C to 661 °C, (17025 accredited calibration included. Traceable to NIST standards.)

  • Secondary Standard PRTs - 5628-20-X

    High-temp PRT, 25.5 Ω, 508 mm (20 in) Includes case, (17025 accredited calibration included. Traceable to NIST standards.)

Description

High-temperature secondary standards

  • Range to 661°C
  • Meets all ITS-90 requirements for resistance ratios
  • Rtp drift < 20 mK after 500 hours at 661°C
  • Calibrated accuracy of ± 0.006 °C at 0 °C

If you’re using block calibrators, furnaces, or temperature points above normal PRT (platinum resistance thermometer) temperatures (420 °C), then these two PRTs are for you. The Fluke 5626 is nominally 100 Ω and the 5628 (formerly Hart Scientific) is nominally 25.5 Ω. Both instruments have a temperature range of –200 °C to 661 °C. They make great working or check standards for calibration work up to the aluminum point.

Using a regular PRT at temperatures above 500 °C exposes the platinum to contamination. If the PRT is used as a reference or calibration standard, contamination is a major problem. SPRTs (standard platinum resistance thermometers), which are more expensive and delicate, can handle the higher temperatures, but with greater risk to the instrument due to shock, contamination, or mishandling. The 5626 and 5628 are designed to reduce the contamination risk through the use of internal protection while not impairing performance.

In addition to the right measurement performance and durability, a PRT for secondary applications should be priced affordably. Fluke Calibration’s new PRTs are inexpensive and come with an accredited calibration. The calibration comes complete with ITS-90 constants and a resistance-versus-temperature table.

Check the temperature range, check the stability, check the price! Who else gives you this much quality, performance, and value for your money? No one!

How to select thermocouple calibration equipment

X = termination. Specify “A" (INFO-CON for 914X), “B" (bare wire), “D" (5-pin DIN for Tweener Thermometers), “G" (gold pins), “J" (banana plugs), “L" (mini spade lugs), “M" (mini banana plugs), “P" (INFO-CON for 1523 or 1524), or “S" (spade lugs).

Additional information

Modèle

5626-12-X, 5626-15-X, 5626-20-X, 5628-12-X, 5628-15-X, 5628-20-X