Description
Key features
- Locate energized and de-energized wires quickly and accurately in walls, ceilings, and floors
- Find breaks or opens and shorts, and identify breakers and fuses easily
- CAT IV 600 V safety rated
- Includes the i400 AC Current Clamp accessory for inducing a tracing signal on the cable when there is no access to bare conductors
General | 2052R Receiver | 2000T Transmitter | i400 AC Current Clamp |
Measurement category | CAT IV 600 V | CAT IV 600 V | CAT IV 600 V, CAT III 1000 V |
Operating voltage | 600 V AC/DC | 600 V AC/DC | 1000 V AC |
Operating frequency | Energized: 6.25 kHz De-Energized: 32.768 kHz | Energized/Loop: 6.25 kHz De-Energized: 32.768 kHz | N/A |
Signal indications | Numeric, bar graph display and audible beep | LEDs and audible beep | N/A |
Response time | Tip Sensor (Energized/De-Energized): 500 ms NCV: 500 ms Battery monitoring: 5 s | Line voltage monitoring: 1 s Battery voltage monitoring: 5 s | N/A |
Current output of signal (typical) | N/A | Energized circuit: High mode: 60 mA rms Low mode: 30 mA rms De-energized circuit: High mode: 110 mA rms Low mode: 40 mA rms Loop mode with test leads: 160 mA rms Loop mode with i400 AC Current Clamp: 385 mA rms | N/A |
Signal voltage output (nominal) | N/A | Energized circuit: High mode: 14 W @ 230 V ac/50 Hz, 3.33 kΩ @ 230 V ac Low mode: 4.6 W @ 230 V ac/50 Hz, 11.5 kΩ @ 230 V ac De-energized circuit: High mode: 31 V RMS, 140 Vp-p, 0.86 W @ 1 kΩ load Low mode: 27.5 V RMS, 120 Vp-p, 0.1 W @ 1 kΩ load Loop mode with test leads: 32 V RMS, 140 Vp-p, 0.87 W @ 1 kΩ load Loop mode with i400 AC Current Clamp: 31 mV, 0.89 W @ 1 Ω load | N/A |
Range detection (open air) | Tip Sensor: Energized Max distance via air: up to 6.1 m (20 ft) Pinpointing: approx. 5 cm (1.97 in) Tip Sensor: De-Energized Max distance via air: up to 4.5 m (14.7 ft) Pinpointing: approx. 5 cm (1.97 in) NCV (40 Hz to 400 Hz) Max. sensitivity: 90 V up to 2 m Min. sensitivity: 600 V up to 1 cm | N/A | |
Current range | N/A | N/A | 400 A |
Basic accuracy | N/A | N/A | 2 % + 0.06 A (45 Hz to 400 Hz) |
Display | |||
Display size | LCD 63 mm (2.5 in) | LEDs | N/A |
Display dimensions (W x H) | 37 mm x 49 mm (1.45 x 1.93 in) | N/A | N/A |
Display Resolution | 240 px x 320 px | N/A | N/A |
Display type | TFT LCD | LEDs | N/A |
Display color | 16-bit | Operating mode LEDs: red Battery status LEDs: green, yellow, red | N/A |
Backlight | Yes | N/A | N/A |
Environmental | |||
Operating temperature | -20 °C to 50 °C (-4 °F to 122 °F) | -20 °C to 50 °C (-4 °F to 122 °F) | -20 °C to 50 °C (-4 °F to 122 °F) |
Operating humidity | 45%: -20 °C to <10 °C or 40 °C to 50 °C (-4 °F to <50 °F or 104 °F to 122 °F) 95% (non-condensing): 10 °C to <30 °C (50 °F to 86 °F) 75%: 30 °C to <40 °C (86 °F to <104 °F) | 45%: -20 °C to <10 °C or 40 °C to 50 °C (-4 °F to <50 °F or 104 °F to 122 °F) 95% (non-condensing): 10 °C to <30 °C (50 °F to 86 °F) 75%: 30 °C to <40 °C (86 °F to <104 °F) | 10 °C to <30 °C (95 %: 50 °F to <86 °F) 30 °C to <40 °C (75 %: 86 °F to <104 °F) 40 °C to <50 °C (45 %: 104 °F to <122 °F) |
Operating altitude | 2000 m (6561 ft) | 2000 m (6561 ft) | 2000 m (6561 ft) |
Transient protection | N/A | N/A | |
Pollution degree | 2 | 2 | 2 |
IP rating | IP 40 | IP 40 | IP 40 |
Drop test | 1 m (3.28 ft) | 1 m (3.28 ft) | 1 m (3.28 ft) |
Mechanical | |||
Power supply | 4 x AA (alkaline) | 8 x AA (alkaline) | N/A |
Power consumption (typical) | 110 mA | High/low mode: 70 mA Loop mode with Clamp: 90 mA Consumption without signal transmission: 10 mA | N/A |
Battery life | Approx. 16 h | High/low mode: approx. 25 h Loop mode: approx. 18 h | N/A |
Low battery indication | Yes | Yes | N/A |
Fuse | N/A | 1.6 A, 700 V, fast-acting, Ø 6 x 32 mm, 50 kA interrupt | N/A |
Maximum conductor size | N/A | N/A | 32 mm (1.26 in) |
Dimensions (L x W x H) | Approx. 183 x 75 x 43 mm (7.2 x 2.95 x 1.69 in) | Approx. 183 x 93 x 50 mm (7.2 x 3.66 x 1.97 in) | Approx. 150 x 70 x 30 mm (5.9 x 2.75 x 1.18 in) |
Weight | Approx. 0.27 kg (0.6 lb) | Approx. 0.57 kg (1.25 lb) | Approx. 0.114 kg (0.25 lb) |
Mechanical | 2000ACC Test Lead Accessory Kit |
Includes | 2x 1 m test leads (red, black), 1x 7 m test lead (green), 2x test probes (black), 2x alligator clips (red, black), 2x outlet blade adapters (red, black), 2x outlet round adapters (red, black) |
Measurement category | CAT IV 600 V (test leads), CAT II 1000 V (test probes), CAT IV 600 V (alligator clips), CAT II 300 V (outlet adapters) |
Operating voltage and current | 600 V, 10 A max. (red/black leads), 600 V, 10 A max. (green lead), 1000 V, 8 A max. (black probe) 600 V, 10 A max. (alligator clips), 300 V, 10 A max. (outlet adapters) |
Operating temperature | 0 °C to 50 °C (32 °F to 122 °F) |
Operating humidity | 10 °C to <30 °C (95 %: 50 °F to <86 °F), 30 °C to <40 °C (75 %: 86 °F to <104 °F), 40 °C to <50 °C (45 %: 104 °F to <122 °F) |
Storage temperature and humidity | 0 °C to 60 °C (32 °F to 140 °F), |
Operating altitude | 2000 m (6561 ft) |
Pollution degree | 2 |
Water and dust resistance | IP 20 |
Drop proof | 1 m (3.28 ft) |
Dimensions | Red/black leads: 1 m (3.28 ft), Green lead: 7 m (22.97 ft), Alligator clips: approx. 95 x 45 x 24 mm (3.74 x 1.77 x 0.94 in), Outlet adapters: 72 x 18 x 18 mm (2.83 x 0.71 x 0.71 in) |
Weight | Approx. 0.4 kg (0.88 lb) |