Heavy Duty TRMS Multimeter

HD160C

Heavy Duty TRMS Multimeter with Temperature

SKU: HD160C Categories: , Tag:

Description

  • Highest voltage capability, measuring to 1500 V DC and 1000 V AC
  • Suitable for testing Solar installations
  • Special sealing for environment and water resistance: IP67 rated
  • Constructed with drop-resistant housing and PCB mounting
  • Measures capacitance, temperature and frequency
  • Superior 10,000 count resolution with bar graph
  • Magne-Grip™ holster, frees both hands for work
  • Digi-Glo™ bright backlight
  • Display 4 digit LCD, 9999 counts, with annunciators, menu features and 41 segment bargraph
  • Polarity indication automatic
  • Input overload indication OL, -OL
  • Auto power-down

What’s Included

  • HD160C
  • Test leads
  • Batteries (installed)
  • Magne-Grip™ holder with magnetic hanging strap

SPECIFICATIONS

FEATUREHD160C
DC Voltage1000.0 mV, 10.000 V, 100.00 V, 1500.0 V
AC Voltage1000.0 mV, 10.000 V, 100.00 V, 1000.0 V
Current100.00 µA, 1000.0 µA, 10.000 mA, 100.00 mA, 400.0 mA, 2.000 A
Resistance1000.0 O, 10.00 kO, 100.00 kO, 1000.0 kO, 10.000 MO, 40.00 MO
Diode
Continuity
Frequency100.00 Hz, 1000.0 Hz, 10.000 kHz, 100.00 kHz, 1000.0 kHz, 10.000 M Hz
Capacitance40.00 nF, 400.0 nF, 4.000 µF, 40.00 µF, 400.0 µF
Temperature-4 °F → 2372 °F (-20 °C → 1300°C)
True-rms
Specifications
DC Volts range:200 mV, 2 V, 20 V, 200 V, 1500 V
DC Volts resolution:0.1 mV
DC Volts accuracy:All ranges ±(0.1 % rdg+2 dgts)
DC Volts input impedance:10 MO
DC Volts OL protection:>1500 V DC/1000 V AC rms
DC Volts transient protection:>12 kV impulse (1.2 µS/50 µS) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V product. This product should not be used in installations where transients exceed 12 kV
AC Volts (45 Hz to 2 kHz) ranges:200 mV, 2 V, 20 V, 200 V, 1000 V
AC Volts (45 Hz to 2 kHz) resolution:0.1 mV
AC Volts (45 Hz to 2 kHz) accuracy:200 mV to 200 V (45-500 Hz) ±(0.8 % rdg+4 dgts),
AC Volts (45 Hz to 2 kHz) accuracy:200 mV to 200 V (500 Hz-2 kHz) ±(1.5 % rdg+5 dgts)
AC Volts (45 Hz to 2 kHz) accuracy:1000 V (50-60 Hz) ±(0.8 % rdg+4 dgts)
AC Volts (45 Hz to 2 kHz) accuracy:1000 V (60-500 Hz) ±(1.5 % rdg+5 dgts)
AC Volts (45 Hz to 2 kHz) input impedance:10 MO
AC Volts (45 Hz to 2 kHz) OL protection:1500 V DC/1000 V AC rms
AC Volts (45 Hz to 2 kHz) transient protection:12 kV impulse (1.2 µS/50 µS) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V product. This product should not be used in installations where transients exceed 12 kV.
DC Current range:200 µA, 2 mA, 20 mA, 200 mA, 2 A
DC Current resolution:0.1 µA
DC Current accuracy:200 µA to 20 mA ±(0.5 % rdg+2 dgts)