Electrician's Multimeter with Non-Contact Voltage

Logo FLuke

117

Designed by electricians. Made by Fluke: an investment in precision

Designed and tested for your safety in your workplace

SKU: 117/EFSP Categories: , Tag:

Description

Compact digital multimeter designed for electricians

The Fluke 117 Electricians Multimeter is a compact, CAT III 600 V, True-rms meter that includes an easy-to-use interface with a bright backlight for darker worksites. It saves you time and enables you to move from job to job more quickly. With a quick turn of the dial you can get measurements for:

  • Resistance
  • Continuity
  • Frequency
  • Capacitance
  • Min/Max/Average

For the everyday

A digital multimeter designed to be hauled everywhere with you, part of your everyday tools. The 117 is built for demanding applications like:

  • Commercial buildings
  • Hospitals
  • Schools

Non-contact voltage detection

Keep yourself safer with integrated VoltAlert™ technology. Fast, go/no go non-contact voltage detection built into your multimeter saves you from having to carry around or find an extra tool to get the work started.

Automatic AC/DC selection

Set the dial and get your measurement quickly with AutoVolt. This automatic AC/DC voltage selector makes it easier for you to get the measurement you need and move on quicker.

Frequently asked questions

What is the difference between the Fluke 115 and the Fluke 117?

While similar, the Fluke 115 and the Fluke 117 meters are designed for slightly different purposes. The Fluke 115 is a compact true-rms digital multimeter that’s great for field service. The Fluke 117 is a designed specifically for electricians. With a quick turn of the dial both units provide measurements for:

  • Resistance
  • Continuity
  • Frequency
  • Capacitance
  • Min/Max/Average

The Fluke 117 offers non-contact voltage detection and has a selectable low-impedance mode to prevent false readings from ghost voltage. The 117 also features automatic selection of AC or DC voltage, depending on what was detected.

Specifications
Maximum voltage between any terminal and earth ground600 V
SafetyIEC 61010-1: Pollution Degree 2
IEC 61010-2-033: CAT III 600V
Fuse for A input11 A, 1000 V FAST Fuse (Fluke PN 803293)
DisplayDigital: 6,000 counts, updates 4 per second
Bar graph33 segments, updates 32 per second
Operating temperature-10°C to +50°C
Storage temperature-40°C to +60°C
Battery type9 volt Alkaline, IEC 6LR61
Battery life400 hours typical, without backlight
Accuracy Specifications
DC millivoltsRange/resolution600.0 mV / 0.1 mV
Accuracy±([% of reading] + [counts]): 0.5% + 2
DC voltsRange/resolution6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy±([% of reading] + [counts]): 0.5% + 2
Auto voltsRange/resolution600.0 V / 0.1 V
Accuracy2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)
AC millivolts¹ True RMSRange/resolution600.0 mV / 0.1 mV
Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
AC volts¹ True RMSRange/resolution6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
ContinuityRange/resolution600 Ω / 1 Ω
AccuracyBeeper on < 20 Ω, off > 250 Ω detects opens or shorts of
500 μs or longer.
OhmsRange/resolution600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ
Accuracy0.9% + 1
Range/resolution40.00 MΩ / 0.01 MΩ
Accuracy5% + 2
Diode testRange/resolution2.00 V / 0.001 V
Accuracy0.9% + 2
CapacitanceRange/resolution1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF
Accuracy1.9% + 2
Range/resolution> 1000 μF
Accuracy5% + 20%
Lo-Z capacitanceRange1 nF to 500 μF
Accuracy10% + 2 typical
AC amps True RMS (45 Hz to 500 Hz)Range/resolution6.000 A / 0.001 A
10.00 A / 0.01 A
Accuracy1.5% + 3
20 A continuous overload for 30 seconds max
DC ampsRange/resolution6.000 A / 0.001 A   10.00 A / 0.01 A
Accuracy1.0% + 3
20 A continuous overload for 30 seconds max
Hz (V or A input)²Range/resolution99.99 Hz / 0.01 Hz
999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 Hz
50.00 kHz / 0.01 Hz
Accuracy0.1% + 2
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.
Mechanical and General Specifications
Size167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
Weight550 g
Warranty3 years